1.4.5
Technical data sheet
MODEL
HC-3
HC-6
HC-7
HC-9
Flow:
(SCFM) @ 100 PSIG
100°F Drying Temperature
(m3/hr) @ 6.89Bar(g)
37.8°C Drying Temperature
301
511
535
909
677
1150
836
1420
Vessel OD
12”
30.48 cm
16”
40.64 cm
18”
45.72 cm
20”
50.8 cm
Desiccant type
IR Activated Alumina
Desiccant / Vessel
223 lbs
101 kgs
397 lbs
180 kgs
502 lbs
228 kgs
620 lbs
281 kgs
Inlet connection
2 NPT
2 NPT
3 FLG
3 FLG
Outlet connection
2 NPT
2 NPT
3 FLG
3 FLG
Afterfilter
(* Option)
AF-350
or AFH-350*
AF-550
or HAF-550*
AF-1000
or HAF-1000*
AF-1000
or HAF-1000*
Voltage 115/1/60
Standard
Consult Factory for other voltages
Cooling Water
9 GPM
34 LPM
16 GPM
61 LPM
20 GPM
76 LPM
25 GPM
95 LPM
Stripping Flow
6 SCFM
10 m3/hr
11 SCFM
19 m3/hr
14 SCFM
24 m3/hr
17 SCFM
29 m3/hr
Cycle time
8 Hour NEMA Cycle –
4 Hours drying/ 4 Hours Regeneration
Outlet Dew Point
Variable
DPDS Control
Adjustable
High Humidity Alarm
Adjustable
Pressure Switch Setpoints
10 PSI Fail to Shift 60 PSI Initiate Cooling
.7 Bar Fail to Shift 4 Bar Initiate Cooling
Cooler outlet high temperature
alarm
105
F
40.6°C
Low regeneration temperature
alarm
Adjustable
Process flow
Downward Regeneration / Upward Drying
Summary of Contents for HC-103
Page 2: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 2 10 17 2013 ...
Page 31: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 31 10 17 2013 SECTION 4 MAINTENANCE ...
Page 50: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 69: ...SAHARA MOISTURE TRANSMITTER Instruction Manual ...
Page 85: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 46 10 17 2013 SECTION 8 CUT SHEETS ...
Page 94: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 050205 Model 1700 IG ...
Page 119: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 47 10 17 2013 SECTION 9 DRAWINGS ...
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......