Reference IR - CS021
Rev 0
Page 1 of 1
07/25/2012
PRESSURE SWITCH
FEATURES
Open frame (skeleton) construction
Compact size
One SPDT output
Hex adjustment (no reference dial)
Pressure connection is ¼” NPT (male)
Set point repeatability is ±1% of adjustable
range
Electrical rating is 15A 125/250/480 VAC
resistive
Weight is approximately 12 oz.
SPECIFICATIONS
CCN
Set Point
Range
Deadband
Over Range
Pressure*
Proof
Pressure**
Storage
Temperature
Ambient
Temperature
Limit
38338893
30 - 300 psi
2.1 - 20.7 bar
1.3 - 4 psi
89.6 - 275.8 mbar
100 psi
above
set point
200 psi above
set point
Max 600
-65 to 160°F
-54 to 71°C
0 to 160°F
-18 to 71°C
38338901
3 - 30 psi
0.2 - 2.1 bar
0.4 - 1.3 psi
27.6 - 89.6 mbar
50 psi
200 psi above
set point
Max 600
-65 to 160°F
-54 to 71°C
0 to 160°F
-18 to 71°C
*
The maximum pressure that may be applied continuously without causing damage and maintaining set point repeatability.
** The maximum pressure to which a pressure sensor may be occasionally subjected, which causes no permanent damage. The
unit may require calibration (e.g. start-up, testing).
Note: Must specify dryer serial number when purchasing replacement.
Summary of Contents for HC-103
Page 2: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 2 10 17 2013 ...
Page 31: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 31 10 17 2013 SECTION 4 MAINTENANCE ...
Page 50: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 69: ...SAHARA MOISTURE TRANSMITTER Instruction Manual ...
Page 85: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 46 10 17 2013 SECTION 8 CUT SHEETS ...
Page 94: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 050205 Model 1700 IG ...
Page 119: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 47 10 17 2013 SECTION 9 DRAWINGS ...
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......