SECTION 1:
(Continued)
A. Regeneration Cycles
1.
Heating
. Hot air directly from the compressor enters the inlet of the HC
and is directed by the inlet 2-way valves into the regenerating tower. This
hot, thirsty air regenerates the bulk of the water from the desiccant. The
air is then directed into the aftercooler where it is cooled, the coalescing
separator where liquid water is removed through the drain trap system,
then into the drying tower where the air is actually dried to its final low
dew point. The heating cycle lasts 90 minutes.