9. OPERATION AND LIGHTING INSTRUCTIONS:
TO TURN ON:
1. From ‘OFF’ position, turn knob 90° counter-clockwise push and hold in.
2. Press the igniter until a flame is established.
3. Release the knob and check that the flame stays on.
4.
If the flame goes out, repeat steps 1 & 2 above.
5.
For maximum temperature, turn knob fully counter-clockwise
.
TO TURN OFF:
1. Turn the knob clockwise until it stops.
2. Depress knob and turn fully clockwise to shut of the gas supply completely
Warning:
A 5 minute complete shut off period is required before the appliance is re-lighted.
In very strong winds, turn off the heater, turn off the gas cylinder valve. Allow the
heater to cool down before moving to a sheltered location.
DO NOT
move the heater while it is hot.
‘AAA’ Battery
Page 9
Install ‘AAA” Battery into electronic igniter (as
illustrated) by unscrewing the cap counter-
clockwise, insert battery with positive terminal
facing “in”.
Replace the cap.