background image

GP-M45J-CX-01A 

4005-CB, 4002-CB Manual 

    RD: JUN 2008 

R.L. 02A 

BA 

Some Authorities do not allow certain warranty exclusions or limitations on how long a warranty lasts or the exclusions or limita-
tions of incidental or consequential damages.  In such cases, the above limitations or exclusions may not apply to you and are not 
intended to do so where prohibited by law.  This warranty gives you specific legal rights.  You may also have other rights which 
vary by each jurisdiction. 

 
                                                              5285 BRADCO BLVD.    MISSISSAUGA, ON,    L4W 2A6 
                                                              2 SCHWANK WAY, WAYNESBORO,  GEORGIA.  30830-8336 
 

SCHWANK                        Ph: 905-712-4766      Fax: 905-712-8336 
INFRASAVE                     Ph: 1-866– INFRASV (463 7278)    Fax: 1-866-724 –9265 

LIMITED WARRANTY CERTIFICATE 

FOR GAS-FIRED INFRA-RED PATIO HEATERS :  4001/2 (-J), 4N11/2 (-J) / 4401/2(-J),  44N1/2(-J)   

4N/L51, 4N/L62 (-J) / 44N/L5, 44N/L6 (-J) SERIES 

 

The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service subject to 
the terms of this document. 
 

COMPONENT PARTS - ONE YEAR WARRANTY

 

Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will supply any component part 
(at our option a new or repaired component part) of the heater, as defined below, excluding any labor, which the Manufacturer’s ex-
amination determines to be defective in workmanship or material for a period of one year (1 year) from the date of installation, 
unless otherwise specified below. This warranty applies to the heater’s original owner, and subsequent transferees and only if the 
unit is installed and operated in accordance with the printed instructions accompanying the unit and in compliance with all applica-
ble installation, building codes and good trade practices. 

 

BURNER AND MANTLE - THREE YEAR WARRANTY 

The Manufacturer warrants the burner and mantle for a period of  three years

(3 years)

 

 

WHAT IS NOT COVERED 

The Manufacturer shall not be responsible for any expenses, including service, labor, diagnosis, analysis, material or transportation 
charges incurred during removal or reinstallation of this product, or any of its components or parts.  All labor or service charges shall 
be paid by the owner.  This warranty does not cover heating products improperly installed, misused, exposed to or damaged by neg-
ligence, accident, corrosive or contaminating atmosphere, water, excessive thermal shock, impact, abrasion, normal wear due to use, 
alteration or operation contrary to the owner’s manual or if the serial number has been altered, defaced or removed.  This warranty 
shall not apply if the input to the heating product exceeds by more than 2% of the rated input on the rating plate.  The Manufacturer 
shall not be liable for any default or delay in performance by its warranty caused by any contingency beyond its control, including 
war, government restrictions, or restraints, strikes, fire, flood, acts of God, or short or reduced supply of raw materials or products.

 

 

WARRANTY PROCEDURE

 

To establish the installation date for any purpose under this Limited Warranty, you must retain the original records that can establish 
the installation date of your unit. If you do not provide such documents, the start date of the term of this Limited Warranty will be 
based upon  the date of unit manufacture, plus thirty (30) days. Failure to maintain the equipment through regular annual service 
maintenance by a qualified service technician shall void the warranty. 

 

LIMITATIONS AND EXCLUSIONS 

This document contains all warranties made by the Manufacturer and may not be varied, altered or extended by any person.  There 
are no promises, or agreements extending from the Manufacture other than the statements contained herein.  THIS WARRANTY IS 
IN LIEU OF ALL WARRANTIES EXPRESSED OR IMPLIED, TO THE EXTENT AUTHORIZED BY THE LAWS OF THE  
JURISDICTION, INCLUDING SPECIFICALLY THE WARRANTIES OR MERCHANTIBILITY OF FITNESS FOR A PAR-
TICULAR PURPOSE. 
It is understood and agreed that the Manufacturer’s obligation hereunder is limited to repairing or replacing parts determined to be 
defective as stated above. In no event shall the Manufacturer be responsible for any alleged personal injuries or other special, inci-
dental or consequential damages. As to property damages, contract, tort or other claim the Manufacturer’s responsibility shall not 
exceed the purchase priced paid for the product. 
All replacement parts will be warranted  for the unused portion of the warranty coverage period remaining on the applicable unit. 

GP-D400-BX-03B 

4000 (-J) SERIES 

WARRANTY  

March 2006 

RL: 3B 

KH 

1-877-446-3727 

1-866-361-0523 

4002-CB, 4005-CB 

Summary of Contents for 4002-CB

Page 1: ...or property damage Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance IF YOU SMELL GAS Extinguish any open flame Don t touch any electrical switch or telephone Go to a neighbor and call your gas supplier immediately Follow any and all instruction from your gas supplier If your gas supplier is not available call the fire department FIE...

Page 2: ...GP M45J CX 01A 4005 CB 4002 CB Manual RD JUN 2008 R L 02A BA ...

Page 3: ...rio USA 30830 L4W 2A6 Phone 706 554 6191 Phone 905 712 4766 Fax 706 554 9390 Fax 905 712 8336 e mail csr schwankgroup com www patioschwank com e mail csr infrasave com www infrasave com TABLE OF CONTENTS TOPIC PAGE NUMBER 1 GENERAL 1 2 INSTALLATION REQUIREMENTS 1 3 GAS SUPPLY 1 3 1 GAS REQUIREMENTS PROPANE 2 4 SPECIFICATIONS 4005 CB 4002 CB PROPANE MODELS 3 5 MAIN COMPONENTS FOR ASSEMBLY 4 6 ASSEM...

Page 4: ...This appliance is a transportable infrared patio deck and garden heater for operation with LPG Liquefied Petroleum Gas The 4005 CB 4002 CB burner is controlled and adjusted by the gas control knob located below the burner and the gas supply is controlled by the valve on the portable propane gas cylinder The gas supply is fed up through the inside of the pole using flexible gas hose These installat...

Page 5: ... fully closed by turning completely clockwise 2 Open cylinder valve for Propane supply 3 Apply the soap solution generously to all connections and hoses 4 Carefully examine all connections in the gas train 5 If bubbles occur there IS a leak Close supply valve completely 6 Retighten the leaking connection and repeat leak test process until ALL leaking has ceased no matter how small the bubbles may ...

Page 6: ...nput rating 38 000 BTUH Low fire input rating 25 000 BTUH Cylinder size 20 lb cylinder not included Cylinder connection QCC 1 Fuel consumption 20 lb cylinder 12 hours at maximum setting ambient temperature affects rate of fuel delivery Net Weight 60 lbs not including cylinder Effective radiant range 8 to 20 foot circle affected by wind and ambient temperature Certifications CSA International USA a...

Page 7: ...ck Finish finish Model 4005 CB 4002 34 Main burner head assembly unit 32 diameter single piece aluminum reflector 34 tall cylinder housing and base Burner post support brackets 3 52 gas supply hose LPG Regulator on hose and QCC 1 fittings 4 ea M6 x 10mm machine screws for burner to upper post assembly 6 ea M6 x 35mm with nuts for post to brackets 3 ea M8 x 15mm bolts for post bracket to heater bas...

Page 8: ... brackets to base L brackets using four 8 x 3 4 bolts and nuts Note Bolt heads face the wheel Position wheel brackets with curve up Align pairs of holes in each end of L brackets to those in opposite sides of the base fasten in place with 8 x 3 4 bolts nuts NOTE Position wheel brackets with curve up Assemble wheels to wheel brackets using axle bolts nuts Attach the 3 post mounting brackets to the ...

Page 9: ...nder cover 3 Attach hose securely to burner 4 Allow burner to rest in post 5 Connect hose to gas cylinder 6 Lift burner and leak test all connections See section 3 1 page 2 section 5 1 next page 7 Fasten burner securely in place with four 1 2 machine screws Page 6 1 Install a washer onto threaded portion of wing bolts 2 Align holes in reflector to those in the brackets at top of burner 3 Secure re...

Page 10: ...he leaking connection and repeat leak test process until ALL leaking has ceased no matter how small If the leak cannot be permanently repaired close the cylinder valve completely and con tact a qualified and licensed gas technician for repair parts and service After successful leak test ensure that the burner assembly and all other components are securely fastened Lift the cylinder cover up from t...

Page 11: ...Install heater on a levelled solid and stable surface Do not install in an explosive environment Keep away from areas where gas vapours are present or inflammable liquids are stored or used In case of strong winds completely shut off the heater and the gas valve In case of very high winds remove reflector dome Do not move the heater when it is hot Do Not operate the heater when the wheels are exte...

Page 12: ...se TO TURN OFF 1 Turn the knob clockwise until it stops 2 Depress knob and turn fully clockwise to shut of the gas supply completely Warning A 5 minute complete shut off period is required before the appliance is re lighted In very strong winds turn off the heater turn off the gas cylinder valve Allow the heater to cool down before moving to a sheltered location DO NOT move the heater while it is ...

Page 13: ...ure is low or regulator is defective Replace empty LPG gas cylinder or defec tive regulator Check gas pressure NG Gas inlet hose is kinked or bent Spider or insect cocoon Check straighten out hose for damage Check for obstructions Burner Unit Carbon on reflector emitter screen or Thick black smoke Clean components as needed check for probable cause and rectify 10 TROUBLE SHOOTING WARNING THIS SECT...

Page 14: ...re gas cylinder in a well ventilated area For more compact storage and to avoid damage the reflector may be removed 12 PREVENTATIVE CARE AND MAINTENANCE The burner area is likely to attract spiders especially inside orifices Once a year the heater should be inspected for spider webs insects and debris around burners and orifices Plugged injectors or orifices will obstruct the gas flow to the burne...

Page 15: ...GP M45J CX 01A 4005 CB 4002 CB Manual RD JUN 2008 R L 02A BA Page 12 ...

Page 16: ...ing products improperlyinstalled misused exposed to or damaged by neg ligence accident corrosive or contaminating atmosphere water excessive thermal shock impact abrasion normal wear due to use alteration or operation contraryto the owner s manual or if the serial number has been altered defaced or removed This warranty shall not apply if the input to the heating product exceeds by more than 2 of ...

Reviews: