16
Part 1
– Chapter 2 – Specifications
GD1 – Installation Guide
Optocoupled logic inputs (programmable)
INX: 10 programmable inputs
Analog inputs (programmable)
AN1 (12 bit)
AN2 (12 bit)
Optocoupled logic outputs (programmable)
OUTX: 4 programmable outputs
VLS2 (optional safety function)
VLS1 (optional safety function)
Analog outputs (programmable)
AN_OUT1 (8 bit) filtered PWM analog output
AN_OUT2 (8 bit) filtered PWM analog output
Opto-relay outputs
"OptoMos" relay: output open if error
Umax = 50 V, Imax = 300 mA
Brake output protected against load short-circuit
Motor brake winding under 24 V
DC
/ 1.5 A (brake supply is
independent from the logic 24 V)
Fieldbus:
- CAN
- Profibus
CANopen
protocol (DS 301 – DSP 402)
PROFIBUS
DP (PP01 to PP04)
Error display
LEDs on front panel + diagnostic via serial link RS 232 +
diagnostic via fieldbus
Motor and application parametrization
Serial link RS 232 or 422 (option)
Bus interface with communication protocol
Automatic functions
Drive adjustment to the motor (AUTO-PHASING)
Servo control adjustment (AUTO-TUNING)
Compliance with the standards:
CE
certification.
"360°" shield connection, equipotentiality
according to the wiring rules
•
GD1-230/cc-PS:
with
FN612-20-06
mains filter
•
GD1-400/cc-PS: with F400 mains filter
•
GD1-400/cc-00 + GDPSxx
EMC requirements: EN 61800-3:2004, Part 3
-
immunity: EN 61000.4-2-3-4-5-6
-
conducted and radiated emissions: class 3
equipment
Electrical standards for industrial machines:
-
EN 60204-1: insulator 2000 V
AC
/ 1 mn
leakage current > 30 mA (EMI filters)
Compliance with the standards:
UL
listing
"360°" shield; equipotentiality according to the
wiring rules
•
GD1-230/cc-PS:
with
FN612-20-06
mains filter
•
GD1-400/cc-PS: with F400 mains filter
•
GD1-400/cc-00 + GDPSxx
GD1 series have been "UL
US
" listed according to UL508C
and UL840 regarding the insulator.
This product was evaluated to:
-
the Third Edition of UL508C, the UL Standard for
Power Conversion Equipment, dated May 2002 for
the UL Listing (USL),
Summary of Contents for GD1-400/05
Page 1: ...GD1 INFRANOR Gem Drive Installation Guide gb Actuator ...
Page 5: ...4 Part 1 GD1 amplifier GD1 Installation Guide PART 1 ________ GD1 AMPLIFIER ...
Page 40: ...GD1 Installation Guide 39 Part 2 GDPS power supply PART 2 ________ GDPS POWER SUPPLY ...
Page 49: ...48 Part 2 Chapter 4 Order code GD1 Installation Guide PART 3 ________ APPENDIX ...