EonStor F16F-R/S4031 Installation and Hardware Reference Manual
Figure 5-9: Installing the BBU
Step 4.
Reset the subsystem
for the new BBU to take effect. The
LED should start flashing to indicate that BBU is being
charged. When the BBU is fully charged, the LED will
light amber constantly.
Figure 5-10: BBU LEDs
NOTE:
A new or replaced BBU takes at least 12 hours to charge to its full
capacity. Reset the subsystem whenever a BBU is replaced or added in
order for the new BBU to take effect.
NOTE:
The life expectancy of a BBU is more than one year. Follow the
procedures above to replace an old BBU with a new one in order to
maintain fault-tolerant subsystem functionalities. An EEPROM will record
the installation date and prompt you for a replacement when the one-year
expectancy is reached.
5-12
Replacing a Faulty BBU