Appendix II Troubleshooting
The following table describes the symptoms causes, and solutions for the problems.
Symptoms
Possible Causes
Solutions
Wrong power connection
Reconnect power cable
Power supply failure
Repair or replace power supply
Unit does not perform
initiation sequence after
powering on
Power PCB fuse damage
Replace the fuse
New camera ID has not been activated
Recycle the power
Protocol or Baud rate Dip switch settings are
incorrectly chosen
Proper set the Protocol and Baud rate.
Wrong camera ID
Reset the camera ID
Unit can’t be controlled after
successful initiation.
Camera is not properly called via keyboard
Use the camera ID to call it
Wrong video cable connection
Reconnect the video cable
No video signal is present.
Video cable broken
Replace the video cable
Unclear down cover
Clean the down cover
Vague image
Manual focus has been set
Set focus mode to "auto"
or
manually adjust the camera focus