![Infinova V1723 Operation/Programming Manual Download Page 27](http://html.mh-extra.com/html/infinova/v1723/v1723_operation-programming-manual_2056944027.webp)
Chapter V Operations Under Different Protocols
5.1 Performances and Features
Prior to operations, please make sure that DIPswitch, baud rate and
address have been set correctly according to related protocol. Refer
to Quick Installation Guide for detailed instructions.
The following table shows the performances and features of the
domes under protocols.
INFINOVA
PELCO-P
PELCO-D(bi-direction)
Up the Coax
Baud Rate
2400/4800/9600BPS 2400/4800/9600BPS
2400/4800/9600BPS
/
Camera Addresses
128
255
254
/
Preset (Controlled by keyboard)
127
128
127
Pattern
4
4
4
AUTOPAN 1
1
1
Area
16
16
16
Home Position
Yes
Yes
Yes
Password Protection
Yes
Yes
Yes
Alarm Contact
Preset Contact
4 Patterns Contact
Autopan Contact
Preset Contact
4 Pattern Contact
Autopan Contact
Preset Contact
4 Patterns Contact
Autopan Contact
AUTOSCAN 1 1
1
5.2 Operations
For detailed operations under different protocols (including
CAMERA CALL-UP, PAN/TILT, TELE /WIDE, OPEN/CLOSE,
FAR/NEAR), please refer to users’ manuals of INFINOVA
keyboard system.
Menu programming of the
domes under all protocols is basically the
same as that showed in Chapter
Ⅳ
. Please follow the instructions
showed on the screen during operation.
For Preset, Autopan, Pattern setup and calling up, shortcut
operations for special functions, please refer to Chapter
Ⅲ
.
The following tables show the operation code via Infinova V2117
system keyboard under different protocols.
Keyboard operation code command under INFINOVA protocol:
Commands
Key Lock
Function
PROGRAM
Set preset 1
~
31,35
~
64,74~91,93,94, 96, 97, 100~127
1
~
31, 35
~
64 , 74~91, 93, 94,
96, 97, 100~127
+
SHOT
OPERATE
Call preset 1
~
31,35
~
64,74~91,93,94,96,97, 100~127
PROGRAM Set/save
autopan
66
+
SHOT
OPERATE Call
autopan
PROGRAM
Set/save pattern 1
70
+
SHOT / 1 PATRN
OPERATE
Call pattern 1
PROGRAM
Set/save pattern 2
71
+
SHOT / 2 PATRN
OPERATE
Call pattern 2
PROGRAM
Set/save pattern 3
72
+
SHOT / 3 PATRN
OPERATE
Call pattern 3
PROGRAM
Set/save pattern 4
73
+
SHOT / 4 PATRN
OPERATE
Call pattern 4
69+SHOT+70/71/72/73+SHOT OPERATE
Repeatedly
call
pattern
68+SHOT PROGRAM
Remote
reset
21