3.
Move the cursor to the ACT entry for the next alarm input in use;
4.
Repeat Steps 1 through 3 until all the desired entries have been
defined.
To set alarm linkage priority
1.
1,2,3,4 four priority in total and the grade become higher in turn.
If several alarm links, the system will response to the one with
higher priority grade;
2.
If priority grades are the same, the system will enter cycle
response mode automatically;
3.
If other operation commands are entered while alarm links occur,
the alarm link operation will be interrupted. The message on
display will show: “ALARM BLOCKED”;
4.
If alarm linkage operation is interrupted, press corresponding
manual command according to different protocols to recover the
former alarm action.
RELAY
Function:
Assign each alarm input with a relay output.
Options:
NONE -
(default) changes of alarm state will not lead to
a relay output.
R 001 -
one relay output.
Operation:
To assign alarm inputs with specific relay:
1.
Move the cursor to the RELAY entry associated with an alarm
input in use;
2.
Deflect the joystick downward (or upward) to select a relay
output;
Move the cursor to the next RELAY entry associated with an
alarm input in use;
3.
Repeat Steps 2 through 3 until all the entries have been defined.
NORMAL STATE
Functions:
Define the normal state of each alarm input.
Options:
NO -
(default) indicate the normal state as normally
open (N.O.).
NC -
set the normal state as normally closed (N.C.).
Operation:
To define the normal state for each alarm input in use.
1.
Move the cursor to the STATE entry associated with a used alarm
input;
2.
Deflect the joystick downward (or upward) to select an appropriate
normal state;
Note:
Since a variety of alarm devices may be utilized, please
refer to the manuals supplied with a particular device to
determine the normal state for the connected alarm input.
3.
Move the cursor to the STATE entry associated with the next alarm
input in use;
4.
Repeat Steps 2 through 3 until all the entries have been
programmed.
Example:
INPUT NO.
1.
2.
3.
4.
NORMAL
1.
2.
3.
4.
BACK
ACTION
PRESET 001
PRESET 022
NONE
NONE
STATE
OPEN
CLOSE
CLOSE
CLOSE
INPUT
1.
2.
INPUT
1.
2.
RETURN
ACT RELAY
PRESET 01 R001
PRESET 02 R001
NORMAL
NO
PRIORITY
NO
3.
4.
3.
4.
PRESET 03 R001
PRESET 04 R001
NO
NO
1
2
3
4
This sample menu indicates:
z
Alarm Input 1 has been defined as normally open, assigned with
Preset 001 as its alarm action, and R001 as its relay output;
z
Alarm Input 2 has been defined as normally open, and assigned
with Preset 002 as its alarm action, and R001 as its relay output;
z
Alarm Input 3 has been defined as normally open, assigned with
Preset 003 as its alarm action, and R001 as its relay output;
z
Alarm Input 4 has been defined as normally open, assigned with
Preset 004 as its alarm action, and R001 as its relay output;
Therefore:
z
When Alarm Input 1 detects an alarm (i.e. Alarm Input 1 changes
from normally closed to open), the domes will be automatically
positioned at Preset 1 and startup relay 1 output;
z
When Alarm Input 2 detects an alarm (Alarm Input 2 changes
from normally open to closed), the domes will be automatically
positioned at Preset 2 and startup relay 1 output.
z
When Alarm Input 3 detects an alarm (i.e. Alarm Input 3 changes
from normally closed to open), the domes will be automatically
positioned at Preset 3 and startup relay 1 output;
z
When Alarm Input 4 detects an alarm (i.e. Alarm Input 4 changes
from normally closed to open), the domes will be automatically
positioned at Preset 4 and startup relay 1 output;
Note:
Dome under the Up the Coax only has one RELAY output.
4.9 AUTOPAN
Dome could scan between two boundary lines and so the dome
could monitor some area continuously under system antomatic
running state.
AUTOPAN parameters including direction, speed, dwell time and
title could be set in AUTOPAN SET menu.
SET CAMERA ID
CAMERA SETUP
SET AE MODE
OSD SETUP
CONFIG HOME POSITION
ALARM ACTION AND STATE
AUTOPAN SET
PATTERN SET
AREA SET
DEFAULT SET
EXIT
AUTOPAN SET
DIRECTION : RIGHT
SPEED :
001
TIME :
002
TITLE :
RETURN
DIRECTION
Functions:
Set the original orientation when dome do horizontal
running.
Options:
RIGHT & LEFT
RIGHT (default):
Start pointing that camera aims at and runs to the
17