25
LT6387 Iss 4 (05/14)
880 FL
Installation Instructions
SECTION NINE To Install the Appliance Continued
CHECKING GAS SOUNDNESS AND RUNNING PRESSURE.
Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.
Turn off the gas supply at the external Isolation valve.
Remove the pressure test point screw from the inlet elbow and connect the pressure gauge.
Turn on the gas to the appliance at the Isolation valve.
Light the appliance as described in section 2.
Check the inlet pressure is 20mbar. +/- 1.0 (Natural Gas) or 37mbar. +/- 1.0 (Propane Gas)
Turn off gas supply, at the isolation valve. Disconnect the pressure gauge and replace the pressure test point screw.
Turn on the supply to the appliance and check the pressure test point for soundness with detection fluid.
Refit the gas connection cover.
Fit the air tray within the location with the burner shelf.
Construction of a false chimney breast front.
Using 50mm K.D Sawn stud-work will provide the required rebate.
The vertical sides of the stud-work should not be less than 502mm from the centre of the firebox. The horizontal stud-work should not be less
than 764mm from the base of the firebox. This will ensure 50mm minimum clearance from the sides and 110mm clearance from the top of the
firebox is maintained.
An insulation material (20mm “Super lux” or equivalent) should be attached to the underside face of the horizontal stud-work directly above
the firebox assembly.
Line the opening with 12mm thick non-combustible material.
FIT LINERS (See Page 9)
LAY FUEL BED
Important: -
Refer to the ‘Heath & Safety Notice located on page 3 of this booklet before laying or replacing any refractory material.
In the event of replacing fuel bed components please use only the specified number of components as illustrated. Only
use fuel bed component provided for this appliance. In the interest of safety and efficiency of your appliance when
replacing the fuel bed it is essential that the existing fuel bed be removed and the new components are replaced correctly
as a complete set.
Lay fuel bed as described under Users Section.
Warning:
It is important that the fuel bed components are positioned as shown in these instructions.
If the fuel bed components are not positioned correctly this may result in damage to the glass.