background image

LT6387 Iss 4 (05/14) 

 

 

880 FL Users Instructions 

 

SECTION ONE Introduction  

 

Consumer Protection Information 

As  manufacturers  and  suppliers  of  heating  products,  we  take  every  care,  as  far  as  is  reasonably 
practicable,  that  these  products  are  so  designed  and  constructed  as  to  meet  the  general  safety 
requirement  when  properly  used  and  installed.  To  this  end,  our  products  are  thoroughly  tested  and 
examined before despatch. 

IMPORTANT  NOTICE:

  Any  alteration  that  is  not  approved  by  the  appliance  manufacturer  could 

invalidate  the  approval  of  the  appliance,  operation  of  the  warranty  and  could  affect  your  statutory 
rights.

 

 

Health and Safety Notice 

Important 

This appliance could contain some of the materials, indicated below, that could be interpreted as 
being injurious to health and safety. It is the users / installers responsibility to ensure that the 
necessary personal protective clothing is worn when handling these materials, see below for 
information. 

Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yarn - 

may 

be harmful if inhaled, may be irritating to skin, eyes, nose and throat.  

When handling,

 

avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks and 

eye protection. After handling wash hands and other exposed parts. If a vacuum is used for cleaning 
the coals or cleaning after servicing / installation it is recommended that it be of the type fitted with a 
HEPA filter. 

Disposal  of  refractory/ceramic  materials

.  To  keep  dust  to  a  minimum  these  materials  should  be 

securely wrapped in polythene and be clearly labelle

d ‘RCF waste’. These materials are not classified 

as ‘hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste. 

 

 

INTRODUCTION 

 

The 880 FL as been designed and tested to the requirements of EN 613 and is suitable for use in 
GB (Great Britain) and IE (Ireland). 

 

The  880  FL  incorporates  a  single  gas  control,  which  selects  ignition  pilot,  with  variable  setting 
between  low  and  high  settings  and  is  operated  via  remote  control.  The  system  is  powered  by  a 
battery pack; therefore no mains electrical supply is required.  

 

Like all appliances incorporating an aerated burner a low frequency noise may be heard, this may 
be more noticeable on the low setting.

  

 

The 880 FL incorporates a safety device in the form of an Oxygen Depletion System, which 
constantly monitors the oxygen in the room and will cause the fire to switch off if the oxygen level 
reduces, for instance due to insufficient ventilation or a blocked flue.  
If this regularly occurs do not attempt to relight the appliance until a qualified engineer has 
checked it, the problem may not be due to lack of air or a defective flue. 

 

The pilot can be left on (standby setting) or the pilot can be extinguished and relit each time the 
fire is used. 

 

 

Summary of Contents for 880FL

Page 1: ...NSTRUCTIONS FOR STANDARD FIRE CAST BASKET Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is fo...

Page 2: ...Fitting 9 SECTION FIVE General 17 INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data 19 SECTION SEVEN Regulations and Warnings 20 SECTION EIGHT Siting the Appliance Flue Class1 21 SECTION NINE To I...

Page 3: ...cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these...

Page 4: ...r The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the appliance must be installed by a competent person and installed in accordance with...

Page 5: ...lit by pressing key the operational mode is switched from manual to Room Thermostat setting and vice versa When Room Thermostat mode is active the display shows the set temperature value and the AUTO...

Page 6: ...ressed key at least for 5 seconds the temperature unit changes from Celsius to Fahrenheit degrees and vice versa Battery level indication Handset When the batteries have to be changed in the handset t...

Page 7: ...ill overheat if fitted incorrectly when fitting the batteries ensure that they are fitted as per the marking on the rear of the holder i e minus of battery against spring e Once the new batteries are...

Page 8: ...clean the glass panel of your 880 FL We recommend you use a Ceramic hob cleaner these are available for all leading super markets i e ASDA TESCO SAINSBURY S Etc Brands of hob cleaning we have tested a...

Page 9: ...h great care The moulded shapes may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose component...

Page 10: ...Layout Make sure that the cross Lighting port are keep clear of any obstruction Place the 2 log shapes along the front edge of the burner top plate Place a single layer of small bark chippings along t...

Page 11: ...structions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place the 2 log shapes along the rear of the air tray assembly Position a single layer of bark chippings along the front edge of the air...

Page 12: ...12 LT6387 Iss 4 05 14 880 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place the 2 log shapes as shown Place the 2 log shapes as shown...

Page 13: ...OUR Fuel Bed Cleaning and Layout Continued 880FL Users Instructions SECTION FOUR Basket Fuel Bed Cleaning and Layout Centralise the Basket into the fire over the Two rivets in Fire Box Position the Tw...

Page 14: ...Position the Two rear shapes as shown Position the Two Front shapes as shown Place a single layer of the small black bark chippings on the burner making sure to leave roughly a 5mm gap between them an...

Page 15: ...Iss 4 05 14 880FL Users Instructions SECTION FOUR Basket Fuel Bed Cleaning and Layout Position 2nd L H shape as shown Place the Thick Middle shape as shown so it rests on the top of the front R H shap...

Page 16: ...wn making sure not to obstruct the Pilot Assembly Position the last shape as shown making sure it does not obstruct the Pilot Assembly Place a single layer of Beige Bark Chips onto the Airtray and a f...

Page 17: ...the inspection covers located on the back and top of the outer firebox This can be obtained by doing the following 880 FL Users Instructions SECTION FIVE General Points Continued Remove the two side c...

Page 18: ...firebox Taking care not to damage the top liner remove the two fixing screw from the top of the inner firebox Carefully pull the inner firebox forward to clear the outer firebox assembly Remove the in...

Page 19: ...460 Mk 580 Oxy pilot 9079 N G 9079 N G Gas Connection 8mm compression semi rigid or rigid Data Badge Location Located on the bottom left hand side of the appliance behind the trim and fascia Battery...

Page 20: ...ent Office IN IE Ireland The appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulation...

Page 21: ...ppliance or if it is a new installation Note A brick or stone chimney with a 125 mm 5 ins minimum diameter flue liner conforming to BS 715 may be used Provided a suitable sealing plate is fitted to th...

Page 22: ...between vertical sides of combustible surround should not be less than 875 mm provided fire is central to the surround and sides do not project more than 150 mm When vertical side forward projection i...

Page 23: ...d onto the firebox assembly and retained using the six off M4 nuts provided Remove the gas connection cover located within the burner shelf left hand side and connect to the restrictor elbow provided...

Page 24: ...he valve carrier Place the Burner Assembly into the Cast Assembly making sure not to trap any wires leads and screw down with the original 3 x screws Position the E D B on the underside of the Basket...

Page 25: ...t be less than 502mm from the centre of the firebox The horizontal stud work should not be less than 764mm from the base of the firebox This will ensure 50mm minimum clearance from the sides and 110mm...

Page 26: ...he fault corrected if the fault cannot be corrected disconnect the fire from the gas supply and seek expert advice Spillage can be caused by a restriction in the flue system down draught or insufficie...

Page 27: ...cuum cleaner nozzle taking care not to damage the pilot head TO REMOVE THE BURNER TRAY BASKET Remove RH and LH side covers undo glass fixing Remove glass panel Remove the loose fuel bed components Dis...

Page 28: ...Undo the Injector tip with a spanner Only remove the injector TIP Refit the injector Tip and retighten with a spanner NOTE The other Injector needs to be left with the appliance or customer Refit the...

Page 29: ...mpression nut on the supply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the...

Page 30: ...date and supported by receipts in each case 5 This warranty is not transferable and relates to the original installation only 6 The Registration Form must be correctly filled out and returned 7 The ap...

Page 31: ...OUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model 880 FL Serial No Date of Purchase This information can be found...

Page 32: ...32 LT6387 Iss 4 05 14...

Page 33: ...ate of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration...

Page 34: ...34 LT6387 Iss 4 05 14...

Page 35: ...35 LT6387 Iss 4 05 14...

Page 36: ...36 LT6387 Iss 4 05 14...

Page 37: ...37 LT6387 Iss 4 05 14...

Page 38: ...38 LT6387 Iss 4 05 14...

Page 39: ...39 LT6387 Iss 4 05 14...

Page 40: ...w Rate Inj tip Restrictor Plate 6255 1 X Bag of Black Chippings 6462 Inlet Cover 6251 Fireplace Frame 6257 Glass Panel 6248 Air Tray 6258 Silicone Sealing Strip 4818 x 2 C Cell Battery 12 Remote Contr...