Infinite Peripherals, Inc.
Page 25
www.ipcprint.com
PP-55 Resident Command Set Version 1.01
Detailed Description
ESC s parameter string
Sets bar code reader parameters
[Code] <1B>H<24>H
<ASCIIZ string>
[Outline] This command sets the specified bar code reader parameters.
• Parameter numbers and values are specified using ASCII decimal
numbers. For example parameter number 169 is written as ‘169’. All,
parameter numbers and values are separated by space. The string ends
with a NULL character (00H). The string consists of paired parameter
number and a value, all separated with spaces.
• An empty parameter string resets the parameters to their default values.
[Default] • The default values for CSE600 Scan Engine are given in the table below.
Paramete
r number
Value
Paramete
r number
Value
Paramete
r number
Value
0
1 23 0 48 0
1 1 24
2 49
0
2 1 25 29 50 1
3 1 26
2 51
1
4 1 27 38 77 0
5 0 28
2 78
1
6 1 29 41 80 7
7 1 30
1 82
0
8 1 31 30 83 0
9 1 34
1 85
0
10 0 35 1 86 0
11 0 36 1 104
10
12 0 37 0 105
0
13 0 38 0 106
13
14 1 39 0 136
30
16 0 40 1 224
0
17 0 41 1 231
0
18 2 42 1 235
0
19 23 43 0 61558
0
20 12 44 0 61559
2
21 0 45 0 61560
55
22 0 46 0 61561
0
[See Also]
ESC q, ESC r, CSE600 Scan Engine Implementation Guide