Application Note
page 27 of 33
V1.7
2022-08-01
XENSIV™ BGT60LTR11AIP shield
60 GHz radar system platform
Power consumption analysis
7
Power consumption analysis
7.1
Duty cycling
The current consumption of the BGT60LTR11AIP MMIC can be optimized by configuring the duty cycle Pulse
width (PW) and the Pulse Repetition Time (PRT). With the default PW of 5 µs, which means the time BGT is active
during one pulsing event, the current consumption values of the MMIC are listed in Table 9.
Table 9
Average current consumption of the BGT60LTR11AIP shield in SPI pulsed mode
PW (µs)
PRT (µs)
Current consumption (mA)
5
250
6.752
5
500 (default)
3.776
5
1000
2.288
5
2000
1.544
The current consumption of the BGT60LTR11AIP shield is measured, as shown in Figure 28.
Figure 28
Current consumption of shield with PW = 5 µs and PRT = 500 µs