Application Note
page 17 of 33
V1.7
2022-08-01
XENSIV™ BGT60LTR11AIP shield
60 GHz radar system platform
Radar MMIC settings configuration
Remove R3 for
autonomous mode
Figure 18
Converting the shield to autonomous mode
Note:
Once a BGT60LTR11AIP shield is converted to autonomous mode, it should NOT be connected to a
Radar Baseboard MCU7 to change the settings via the GUI. Only, resistor values mentioned in
Table 5 and Table 6 are recommended to be soldered on the shield in order to achieve the desired
settings.