9.1.2
Read-only registers for protected configuration registers
9.1.2.1
Register RWDCFG0
RWDCFG0
RMAP: X
Address:
07
H
Read-only watchdog configuration 0
PAGE: 2
Reset Value:
9B
H
7
6
5
4
3
2
1
0
WWDETHR
WWDEN
nu
WWDTSEL
WDCYC
r
r
r
r
r
Field
Bits
Type
Description
WWDETHR
7:4
r
Window watchdog error threshold ACTIVE
0
H
0
1
H
1
...
F
H
15
Reset: 9
H
WWDEN
3
r
Window watchdog enable STATUS
0
B
, disabled
1
B
, enabled
1
B
nu
2
r
Not used
WWDTSEL
1
r
Window watchdog trigger selection ACTIVE
0
B
, external WDI input used as WWD trigger
1
B
, WWD is triggered by SPI write to WWDSCMD register
1
B
WDCYC
0
r
Watchdog cycle time ACTIVE
0
B
, 10 µs tick period
1
B
, 100 µs tick period
1
B
OPTIREG
™