13
Function Overview
Function P2, After start
(
ECOS module EM-07)
Function
A fter star t; A t the end of a whole session it is possible to allow one extr a time
of 3 0 seconds. T o obtain this time the down key has to be pr essed. T his setting
pr ovides a solution for machines, which have to be connected for a shor t per iod
of time after the pr ogr ammed time has expir ed, e.g. to open the electr ic door of
a washing machine.
Setting
Descr iption
Default
00
A fter start is disabled
1
01
A fter start is enabled
Function P3, Display indication
(
ECOS module EM-14)
Function
Display indication, choice between
of
.
Setting
Descr iption
Default
00
D isplay during stand by one point (
), during the prior time, main time
and post time tw o hy phens w ill be display ed (
).
1
01
D isplay indication in minutes
Function P4, Reduction of the main time
(
ECOS module EM-13)
Function
Reduction of the main time
Setting
Descr iption
Default
00
M ain Time reduction disabled
1
01
M ain Time reduction enabled
N ote:
S ee
P 7
for configuration.
Function P5, Pause during the main time
Function
P ause dur ing the main time
Setting
Descr iption
Default
00
P ause during the main time disabled
1
01
P ause during the main time enabled
note:
D uring a pause situation the remaining time w ill be intermittently indicated (if display indication is
set to 1 (
P 3
)). N ote; this function w orks only w ith long distance board!
Function P6, Main time during the pause
Function
M ain time dur ing the pause
Setting
Descr iption
Default
00
M ain time stops during the pause
1
01
M ain time continues during the pause
Function P7, Main time reduction configuration
Function
M ain time r eduction dur ing the main time
Setting
Descr iption
Default
00
The main time w ill be finished immediately w hen the dow n key is pressed.
0
01
It is possible to shorten the main time during the main time or prior time (by
means of the dow n key ). When the main time is shortened it w ill alw ay s
start w ith w hole minutes.
note: When activ ating this function, function
P 4
has to be enabled as
w ell (ev en if the prior-time is not used).
02
The dow n key w ill be blocked during the main time. S o during the prior-time
the main time can be reduced beforehand, as long as
P 4
is enabled.
O therw ise main time can not be reduced.
13
13
13
13
Summary of Contents for MicroTimer 2400
Page 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...