background image

6    -    MicroTimer 2400

Possebilities

 Basic functioning (without ECOS modules)

In the basic version during stand-by a point 

 

(.) will be shown on the display.

As soon as the main time is connected the display will change into two hyphens 

 

(--).

 Time per periode (Main Time)

The maximum period of time to be programmed in the MicroTimer® is 15 minutes. The main time starts after pressing the
timer-key, after inserting a coin or by means of a continuous external drive.

 Output

The MicroTimer® output is programmable. It may be chosen between the standard  “continue”  output,  which  means  that
both relays are activated during main time, and a “pulse” output, which means that a pulse is generated at the beginning
and the end of the main time.

 Pause

The operator may choose either to allow the creation of a pause during the main time or not. If a pause is allowed, it can
be created by pressing the Start/Pause key. The operator can also choose  between  interrupting  and  continuing  the  main
time during the pause mode

Summary of Contents for MicroTimer 2400

Page 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...

Page 2: ......

Page 3: ...ttp www inepro com Table of Contents 1 Introduction 2 1 Design 2 Extra functioning 3 2 Versions 5 Possebilities 6 1 Basic functioning 7 Settings 8 1 Function Menu 8 2 Function Overview 15 Specificatio...

Page 4: ......

Page 5: ...new device contains materials which can be recycled and then reused At the end of life specialized companies can dismantle the device to materials which can be reused in order to recycle and reuse For...

Page 6: ......

Page 7: ...Introduction PartI...

Page 8: ...rior time During the prior time the length of the main time will be shown intermittently on the display During the prior time it is possible to reduce the main time if necessary The prior time can als...

Page 9: ...3 Versions De versies There is one type of MicroTimer available as the functioning of the MicroTimer mainly depends on the additional software modules and the settings...

Page 10: ......

Page 11: ...Possebilities PartII...

Page 12: ...ting a coin or by means of a continuous external drive Output The MicroTimer output is programmable It may be chosen between the standard continue output which means that both relays are activated dur...

Page 13: ...Settings PartIII...

Page 14: ...use key Up or the Stop key Down 7 Quit and confirm the set value by pressing the Start Pause key Up and the Stop key Down simultaneously The function menu is shown again and another function can be se...

Page 15: ...umulatively the total main time Value Description Default 1 255 Max number of coins 1 Note The v alue of this setting has to be at least 1 Function F5 Minimum amount of coins ECOS module EM 05 Functio...

Page 16: ...ay 1 activity T he value of this register represents the number x 1000 minutes e g 5 5000 minutes When the counter reaches zero the message will appear on the display T his is the standard message to...

Page 17: ...ter is read back to front as follows C ounter index Example V alue 1 1 2 3 3 7 4 5 5 0 6 0 In this example the total running time amounts to 005731 minutes V alue 1 0 2 0 3 0 4 0 5 0 6 0 Note Resettin...

Page 18: ...sec p m 800 849 30 sec p m 400 449 22 sec p m 850 899 30 sec p m The time adjustment is preprogrammed and depend on the maximum number of running hours set in F6 F7 This table shows the prolongation...

Page 19: ...during the main time Function Pause during the main time Setting Description Default 00 Pause during the main time disabled 1 01 Pause during the main time enabled note During a pause situation the r...

Page 20: ...yment during main time Function Payment during main time Setting Description Default 00 Pay ment during main time is disabled 0 01 Pay ment during main time is enabled note The maximum amount of coin...

Page 21: ...Specifications PartIV...

Page 22: ...nsumption 25 mA maximaal Fuse 500mA Supply voltage for the low voltage model Voltage range A C 12 V A C 24 V A C Voltage range DC 12 V DC 35 V DC Stroomopname 250 mA maximum Outputs Maximum rupturing...

Page 23: ...Appendix PartV...

Page 24: ...three button from a greater distance maximum 50 meters E O utput 2 O utput 2 is exclusiv ely switched by the main time function F1 The relay s are potential free or dry ie they are simply switches tha...

Page 25: ...tput signal depends on the settings in Functie P0 Connection diagram with external connections and a live output Use this diagram to connect one or two devices A B that must be fed by the main 230V AC...

Page 26: ...ection diagram with external connections and uncharged neutral output Use this diagram to connect one or two devices A B that relays power to one of their outputs and must be electronically fed trough...

Page 27: ...on print 2 Quick start function Dip switches ON blocked OFF activated 4 Enable disable the Start button 3 Enable disable the Timer button 2 Enable disable the Stop button 1 Enable disable the Function...

Page 28: ......

Reviews: