IDS 410/422 User's Manual
22
Scale Parameters
I/O PORT Parameters
No
Parameter Name
Default
Maximu
m
Pass Field Setting
23
Serial port 1 mode
4(8N1)
6
2
24
Serial port 1 baud rate
1(9600)
7
2
25
Serial port 2 mode
4(8N1)
6
2
26
Serial port 2 baud rate
1(9600)
7
2
27
TX2 control / Station Id
255
255
1
28
TX2 Data Format
2 (condec) 4
2
30
Autoprint LF after CR
1 (yes)
1
2
31
End Of Print character
13 return 255
2
32
Print label 1
16 char 2
33
Print label 2
16 char 2
34
Print label 3
16 char 2
35
Print code 1
3 codes 2
36
Print code 2
3 codes 2
37
Print code 3
3 codes 2
38
Print code 4
3 codes 2
39
TTL remote control
0 (NO)
1
2
No. Parameter Name
Default
Max
Value
Pass Field Setting
1
Loadcell mv/v
3
3
3
2
Digital filter
9
18
3
3
Display Update Rate
1
200
3
4
Motion delay time
6
250
3
5
Motion band
6
250
3
6
Motion blanks display
0 (no)
1
3
7
Zero tracking delay
0
250
3
8
Zero tracking band
12
250
3
9
Push button zero percent
100
100
3
10 Primary units type
1 (lb)
6(oz)
3
11 Decimal point position
0
4
3
12 Count-by
1
100
3
13 Alternate units type
2 (kg)
6(oz)
3
14 Alt decimal point
1
4
3
15 Alternate count-by
5
100
3
16 Alt conversion factor
45,360
3
17 Full Scale display digits
10,000
120,000 3
18 Over Weight dd
10,200
120,200 3
19 Deadload offset
3
20 Disable Power-On Zero
1
1
3
Summary of Contents for IDS 410