SET OPERATION PARAMETERS
This section describes the operation parameters of the IDS 410/422.
Access Operation Parameters and Parameter Functions
The parameters are accessed by holding the GROSS/NET key down and then pressing the
UNITS key. The numeric display prompts "CFG xx", where xx is the currently selected
parameter. Use the alternate key functions to select a parameter. Press the
enter
key to begin
parameter data entry. Press the
clear
key to exit configuration mode and store the parameter data
into memory.
Parameter data entry uses the alternate keyboard functions (
clear, item, +, -, enter
). To
enter/change numeric data, use the
item
key to select a digit to change. The blinking digit is the
currently selected digit. Use the (
+)
and (
-
) keys to increase or decrease the selected digit. Press
the
enter
key to accept the displayed number or press the
clear
key to discard the changes.
EXAMPLE: Set the full-scale graduations (parameter 17) to 5000 -
Hold the GROSS/NET key down and press the UNITS key. Press the
item
key to select the
second digit from the right, press the (
+
or
-
) until the digit is 1. Press the
item
key. Press the (
+
or
-
) key until the far right digit is 7. Press the
enter
key. The display prompts "10000". Press the
item
key until the far left digit blinks. Press the (-) key 1 time to change the 1 to 0. Press the
item
key. Press the (+) key 5 times to change the 0 to 5. Press the
enter
key to exit parameter 17 data
entry. Press the
clear
key to exit configuration mode and store the parameter data into memory.
Operation Parameters Reference Tables
The reference tables provide an overview of the operation parameters. The sections following the
reference tables describe the setup parameters in detail and the procedures for modifying them.
Use the 'Field Settings' column of the reference tables to document any changes to the setup
parameters.
Reference Table column heading descriptions:
No.:
Use this number to access the parameter to be modified. For example to modify the
Digital Filter enter CFG 3.
Parameter Name:
The name of the parameter.
Default Value:
The value set at the factory. The Parameter Function "Initialize Operation
Parameters to Factory Defaults" sets the parameter to this value.
Maximum Value:
The maximum value for numeric parameters, the maximum number of
characters for alphanumeric parameters.
Password Level
: The IDS 410/422 has 3 password levels. Level 1 requires entering password-1
before accessing the parameter. Level 2 requires password-2. Level 3 requires password-2 and
the Lock Switch to be in the unlocked position.