![IndigoVision 10-Channel Rack Hardware Manual Download Page 20](http://html1.mh-extra.com/html/indigovision/10-channel-rack/10-channel-rack_hardware-manual_2053917020.webp)
20
consideration of equipment nameplate ratings should be
used when addressing this concern.
•
Reliable Earthing
— Reliable earthing of rack-mounted
equipment should be maintained. Particular attention
should be given to supply connections other than direct
connections to the branch circuit (e.g. use of power strips).
1. Insert the 10-Channel Rack device into a 19" Rack cabinet.
2. Attach the Rack to the cabinet using four screws (not included).
Caution
If more than two 10-Channel Racks are mounted on top of each other in
the same cabinet, you must ensure that there is adequate air circulation
to keep all units within the specified operating temperatures.
IndigoVision recommends that you leave a 1U gap above and below each
Rack. You may also want to consider fitting an exhaust fan to the cabinet.
3. Connect the power supply to the backplane (see
Figure 4
on
page 18).
Notice
The 10-Channel Rack does not have a power switch. When power is
connected, the system is on. To turn the unit off, disconnect the power.
You have now completed configuration of the 10-Channel Rack.
Resetting the Rack Card to Factory Defaults
If necessary, you can reset the network security information
(password and IP firewall) for the Rack video cards. To do this,
follow the instructions in
"Serial Configuration" on page 1
and