![IndigoVision 10-Channel Rack Hardware Manual Download Page 19](http://html1.mh-extra.com/html/indigovision/10-channel-rack/10-channel-rack_hardware-manual_2053917019.webp)
19
Digital Video Out
BNC Connector
PTZ & Alarm
Connector
Audio
Connector
Slot 1 Console Port
Slot 1
Power
Connectors
Figure 5
Backplane view of 10-Channel Rack (receiver)
Digital Video Out is a composite video signal generated from the
decompressed digital video received from the network.
Step 5: Installing the Rack into a Cabinet
When rack-mounting your 10-Channel Rack, please consider the
following:
•
Elevated Operating Ambient
— If installed in a closed or
multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than
room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with
the specified 50ºC maximum ambient temperature (Tma) of
the unit.
•
Reduced Air Flow
— Installation of the equipment in a rack
should be such that the amount of air flow required for safe
operation of the equipment is not compromised. To
facilitate this, an air gap of at least 6cm on both sides of the
unit is recommended.
•
Mechanical Loading
— Mounting of the equipment in the
rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
•
Circuit Overloading
— Consideration should be given to
the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate