Example: Hydraulic unit G200.2
a
Filler neck
b
Fill level indicator
c
Accumulator drain valve
d
Monitoring (level and temperature)
e
Oil drain plug
f
Monitoring (system pressure)
X
Hydraulic fluid filter hydraulic fluid HLPD32 (VG32)
Y
Filter bowl
Remove the hydraulic unit base plate (b) and clean the hydraulic fluid tank.
3. Replace the seal at the hydraulic unit base plate (b).
4. Screw on the hydraulic unit base plate (b) again, paying attention to the correct
seating of the seal and the base plate (b).
5.
Dispose of the fluid in the filter bowl (Y); do not refill into the
hydraulic tank.
Maintenance Summary - 4.000 Operating hours