42
462
M o u n t i n g t h e I N T- 4 6 2
C o n n e c t i n g a n d C o n f i g u r i n g t h e I N T- 4 6 2
W i r i n g S p e c i f i c a t i o n s
The INT-462 uses a removeable 15 pin screw terminal for wiring connection. The
following wiring practices are recommended when connecting to the INT-462:
Wire Size: 18 - 26 AWG.
Strip Length: 0.197” (5mm).
Screw Torque: 3.0 lb-in (0.33 N-m).
P o w e r a n d M o t o r C o n n e c t i o n a n d
S p e c i f i c a t i o n s
M o t o r P o w e r ( + V )
Motor power for the INT-462H/IB462H will have the same recommended
specifications as found in
Section 1.5: Power Supply Requirements
of this
document.
The power supply ground will be connected to Pin 1 (GND) and the DC
output to Pin 2 (+V). See the
Minimum Required Connections
figure in this
appendix for a connection diagram.
Figure 2.1.2: Mounting the INT-462
A
B
C
A
B
C
#6-32 or (M3.5) Threaded Screw*
#6 or (M3.5) Split Lock Washer*
#6 or (M 3.5) Flat Lock Washer*
#6-32 Threaded
IB462H/INT-462
TI-462H Isolating
Thermal Pad
Heatsink
WARNING! The IB462H Driver must be mounted to a Heat Sink at all
power levels. The Isolated Thermal Pad supplied with the H-462H Heat
Sink must aslo be used.
* The t or que specificat ion for t he 6 -3 2 m ount ing scr ews is 5 .0 t o 7 .0 lb-in (0 .6 0 t o 0 .8 0 N-m ).