462
L E D I n d i c a t o r s
G r e e n
The green LED is powered by the on-board +5V supply and indicates a
“power on” condition when illuminated.
R e d
The red LED is controlled by the fault protection circuitry on the INT-462H.
If the red LED is illuminated, remove power and check for a system fault.
Verify that the current adjust resistor is in place and the correct value. A fault
condition can only be cleared by cycling power or toggling the RESET input
at Pin 11 of the terminal strip.
M i n i m u m R e q u i r e d C o n n e c t i o n s
Figure 2.1.7 illustrates the connections required to operate the INT-462/IB462H
Interface board/driver combination.
Figure 2.1.7: Minimum Required Connections
Direction
Step Clock
A
B
B
A
Output Current Adjustment
Resistor (See Table A.4)
Shown using the on-board
+5V for opto supply, ENOFF
mode for current reduction.
Driver in Full Step mode.
ENOFF/ENON
PIN 1
+12 to +40
VDC Supply
OPTO/+5V