Vacuum control
1. To start the pump in vacuum control, press the [start vacuum control] button.
Note
Using a Hydrostatic pressure sensor gives a more accurate level regulation, as well as a better
visualization. The sensor can be connected inside the canopy, and should be place in a level indication
tube which level should be regulated. Every red marking on the sensor cable represents one meter,
this is used to determine the sensor height in the next pages
If vacuum control is selected the ECOMIZER-PRO will automatically adjust the RPM to regulate the
groundwater to the desired level. If you do not use a hydrostatic pressure sensor the visualization will
be scaled from 0M to 10M.
1.
Check “use level sensor” if you’ve connected and installed the hydrostatic pressure sensor.