3.20 TECHNICAL DATA.
- Flue temperature values refer to an air inlet
temperature of 15°C and delivery temperature
of 50°C.
- The data relevant to domestic hot water
performance refers to a dynamic inlet pressure
of 2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
- (***) Yields refer to the lower heating value.
- (*) Specific capacity “D”: domestic hot water
flow rate corresponding to an average increase
of 30K, which the boiler can supply in two
successive withdrawals.
- (**) When the boiler is connected to an external
storage tank.
Nominal heat input
kW (kcal/h)
32.6 (28042)
Minimum heat input
kW (kcal/h)
4.2 (3648)
Nominal heat output (useful)
kW (kcal/h)
32.0 (27520)
Minimum heat output (useful)
kW (kcal/h)
4.0 (3440)
(***) Efficiency 80/60 Nom./Min.
%
98.1 / 94.3
(***) Efficiency 50/30 Nom./Min.
%
106.5 / 105.3
(***) Efficiency 40/30 Nom./Min.
%
107.7 / 105.9
Heat loss at casing with burner On/Off (80-60°C)
%
0.47 / 0.30
Heat loss at flue with burner On/Off (80-60°C)
%
0.03 / 2.20
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature (max work field)
°C
20 - 85
System expansion vessel total volume
l
5,8
Expansion vessel factory-set pressure
bar
1,0
Water content in generator
l
3,2
Head available with 1000 l/h flow rate
kPa (m H
2
O)
31,0 (3,16)
(**) Hot water production useful heat output
kW (kcal/h)
32,0 (27520)
(**) Domestic hot water adjustable temperature
°C
30 - 60
(**) Domestic hot water flow limiter
l/min
Automatic
(**) Min. pressure (dynamic) domestic hot water circuit
bar
0,3
(**) Domestic hot water circuit max. working pressure
bar
10
(**) (*) Specific capacity “D” UB Immergas Inox 80-2 according to EN 625
l/min
21,8
(**) (*) Specific capacity “D” UB Immergas Inox 120-2 according to EN 625
l/min
26,6
(**) (*) Specific capacity “D” UB Immergas Inox 200-2 according to EN 625
l/min
37,2
(**) Drawing capacity in continuous duty with UB Immergas (ΔT 30°C)
l/min
15,3
Weight of full boiler
kg
45,7
Weight of empty boiler
kg
42,5
Electrical connection
V/Hz
230 / 50
Power input
A
0.78
Installed electric power
W
110
Pump consumption
W
70
Fan power consumption
W
33
Equipment electrical system protection
-
IPX5D
Max temperature of combustion products
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
30
Weighted CO
mg/kWh
12
Type of appliance
C13 / C13x / C33 / C33x / C43 / C43x / C53 / C63 /
C83 / C93 / C93x / B23p / B33
Category