INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
Key:
1 - Fumes hood
2 - System pressure switch
3 - Boiler pump
4 - Domestic hot water flow switch
5 - Gas valve
6 - Domestic hot water probe
7 - System filling valve
8 - Flue safety thermostat
9 - Delivery probe
10 - Rapid heat exchanger
11 - Safety thermostat
12 - Combustion chamber
13 - Ignition and detection electrodes
14 - System expansion vessel
15 - Burner
16 - Vent valve
17 - Manifold
18 - System draining valve
19 - By-pass
20 - 3 bar safety valve
N.B.: connection group (optional)
1.15 BOILER COMPONENTS.