22
A
B
C
D
E
F
G
A
++
A
+
A
B
C
D
E
F
G
XL
24
kW
C
NIKE STAR 24 4 ERP
B
56
dB
3.21 TECHNICAL PARAMETERS FOR COMBINATION BOILERS (IN COMPLIANCE WITH REGULATION 813/2013).
Efficiencies in the following tables refer to the gross calorific value.
Model/s:
Nike Star 24 4 ErP
Condensing Boilers:
NO
Low temperature boiler:
NO
Boiler type B1:
YES
Co-generation appliance for central heating:
NO
Fitted with supplementary heating system:
NO
Mixed heating appliance:
YES
Element
Symbol
Value
Unit
Element
Symbol
Value
Unit
Nominal heat output
P
n
24
kW
Seasonal energy efficiency of central
heating
η
s
75
%
For central heating only and combination boilers: useful heat output
For central heating only and combination boilers: useful efficiency
At nominal heat output in high tempera-
ture mode (*)
P
4
23,6
kW
At nominal heat output in high tempera-
ture mode (*)
η
4
82,1
%
At 30% of nominal heat output in a low
temperature mode (**)
P
1
6,7
kW
At 30% of nominal heat output in a low
temperature mode (**)
η
1
78,0
%
Auxiliary electricity consumption
Other items
At full load
el
max
0,014
kW
Heat loss in standby
P
stby
0,210
kW
At partial load
el
min
0,014
kW
Ignition burner energy consumption
P
ign
0,000
kW
In standby mode
P
SB
0,003
kW
Emissions of nitrogen oxides
NO
X
138
mg /
kWh
For mixed central heating appliances
Stated load profile
XL
Domestic hot water production efficiency
η
WH
78
%
Daily electrical power consumption
Q
elec
0,119
kWh
Daily gas consumption
Q
fuel
25,631
kWh
Contact information
IMMERGAS S.p.A. VIA CISA LIGURE, 95 - 42041 BRESCELLO (RE) ITALY
(*) High temperature mode means 60°C on return and 80°C on flow.
(**) Low temperature mode for condensation Boilers means 30°C , for low temperature boilers 37°C and for other appliances 50°C of return tem-
perature.
3.22 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013).
Parameter
value
Annual energy consumption for the heating function (Q
HE
)
91,0 GJ
Annual electricity consumption for the domestic hot water function
(AEC)
26 kWh
Annual fuel consumption for the domestic hot water function (AFC)
19 GJ
Seasonal space heating energy efficiency (η
s
)
75 %
Water heating energy efficiency ( η
wh
)
78 %
For proper installation of the appliance refer to chapter 1 of this booklet (for the installer)
and current installation regulations. For proper maintenance refer to chapter 3 of this
booklet (for the maintenance technician) and adhere to the frequencies and methods
set out herein.
Summary of Contents for Nike Star 24 4 ErP
Page 18: ...18 3 4 3 2 2 4 1 INSTALLER USER MAINTENANCE TECHNICIAN ...
Page 27: ...27 ...