D.h.w. exchanger preheating.
When this function is active
it is possible to maintain the d.h.w. exchanger at a constant
temperature of 50 °C in order to have a quicker supply of
domestic hot water.
D.h.w. exchanger preheating
LED flashing
(slow)
Off
(Standard setting)
LED 2
On
LED 11
Gas G110 – China Gas.
The setting of this function serves to
adjust the boiler to work with the gases of the first family.
Gas G110 -
China Gas
(first family gas)
LED flashing
(slow)
Off
(Standard setting)
LED 2
On
LED 11
Relay 1 operation*.
Relay 1 operation
(switching, free contacts)
LED flashing
(slow)
Off
LED 2
Main zone command
(Standard setting)
LED 3
General alarm
LED 6
Central heating phase on
LED 7
External gas valve powered
LED 8
Relay 2 operation*.
Relay 2 operation
(single, contacts energised
with SELV contact in series)
LED flashing
(slow)
Off
(Standard setting)
LED 2
Remote filling
LED 4
General alarm
LED 6
Central heating phase on
LED 7
External gas valve powered
LED 8
Secondary zone command
(from S20 on relay
card contact)
LED 9
Relay 3 operation*.
Relay 3 operation
(single, free contacts)
LED flashing
(slow)
Off
(Standard setting)
LED 2
Aqua Celeris system powered
LED 5
General alarm
LED 6
Central heating phase on
LED 7
External gas valve powered
LED 8
*
In case of connection to the relay control board
(op-
tion).