35
Ext sens
open
100 K
47
22
Short circuit
Ω
K
K
10 K
Ω
Ω
Ω
Set point
82°C
71
60
49
38
27
°C
°C
°C
°C
°C
(*)
Morsetto VII
VII
eB
U
S
FA
0-1
0
V
1
2
VI
I
Pin 1: eBUS (F A) risp. Uscita 0-10 V
Pin 2: (massa BUS / 0-10 V)
Morsetto I
I
1
2
3
4
5
6
7
8
9
10
AF
K
F
/S
PF
V
F
F9
F8
F6
F5
F3
F2
F1
FB
R
I
Pin 1:
Pin 2: Tampone centro sensore / Telereg. Circ di risc. 1 (sensore amb.)
Pin 3: Tampone sopra sensore / Telereg. Circ di risc 1 (valore nom.)
Pin 4: Massa sonda di mandata circ. risc. 2 / Telereg circ. 1 massa
Pin 5: Sonda mandata circ. risc. 2
Pin 6: Sonda bollitore
Pin 7: Massa Sonda mandata Globale
Pin 8: Sonda mandata globale
Pin 9: Sonda esterna
Pin 10: Massa sonda esterna / Massa sonda Mandata Cir. Risc. 1
Tampone sotto sensore
VF
VF
SPF
SPF
KF
AF
AF
1
2
V
SP
F
F1
2
F1
1
VF
Morsetto V
V
Pin 1: Sonda
Pin 2: Sonda (sotto) bollitore / sensore multifunzione 2
di mandata circ. risc. 1 / sensore multifunzione 1
VF
SPF
1
2
VI
II
PT
10
00
F1
4
F1
3
Morsetto VIII
F13
F14
Pin 1: Sensore GC 2 /
Pin 2: Sensore solare 1 / sensore relè multifunzione 4
Sensore solare 2 / sensore relè multifunzione 3
Sensore PT 1000
Morsetto III
III
1
2
3
II
I
IM
P
0-1
0
V
F1
7
F1
5
3
1
FB
R
Pin 1: Ingresso
Pin 2: M
0-10V (da abilitare)
assa
F15
F17
1
2
3
4
IX
L
H
BU
S
MorsettoIX
IX
H
CAN Bus Pin 1 = H (data)
CAN Bus Pin 2 = L (data)
CAN Bus Pin 3 = - (massa, Gnd)
CAN Bus Pin 4 = + (alimentazione 12V)
L
-
+
1
2
3
Y2
4
5
6
7
Y3
1
2
3
Jp1
1
2
3
Y4
4
DL1 DL2 DL3
1 2
3
Y1
4 5
6
A1
SW1
GCI
eB
U
S
-
eB
U
S
+
+
24
V
0 1
2
3
45
6
7
8
9
1
2
3
Y4
4
SEGNALAZIONE
ALLARME
COMANDO POMP A
CIRCUITO COLLETT ORE
CONTROLLO POM PA MODULANTE
1
2
3
Y2
4
5
6
7
0-10 V
Modbus - B
Modbus - A
PLC /
BMS
( - )
( - )
( + )
eBUS remoto
(Gestore di cascata esterno)
SET POINT EMERGENZA
Inserire resistenze in base alla tabella (*)
Instructions for the installer
Description of terminal board for low voltage connections.
To be connected to the GCI
To be connected to remote control devices
GCI terminal board description
Ext sens
open
Short circuit
Set point
PUMP CONTROL
MANIFOLD CIRCUIT
ALARM SIGNAL
Terminal IX
Terminal III
Terminal VIII
PT 1000 sensor
CAN Bus Pin 1 = H (data)
CAN Bus Pin 2 = L (data)
CAN Bus Pin 3 = - (ground, Gnd)
CAN Bus Pin 4 = + (12V power supply)
Pin 1: 0-10V input (to be enabled)
Pin 2: Ground
Pin 1: CM2 sensor / Solar sensor 2 / Multifunction relay sensor 3
Pin 2: Solar sensor 1 / Multifunction relay sensor 4
Pin 1: Flow sensor heat. circ. 1 / Multifunction sensor 1
Pin 2: Probe (under) storage tank / multifunction sensor 2
Pin 1: eBUS (F A) or 0-10 V output
Pin 2: (ground BUS / 0-10 V)
Pin 1: Buffer under sensor
Pin 2: Sensor centre buffer / Remote. Heat. circ. 1 (room sensor)
Pin 3: Buffer over sensor / Remote. Heat. circ. 1 (nom. value)
Pin 4: Flow probe ground heat. circ.2 / Remote ground 1 circ.
Pin 5: Flow probe heat. circ. 2
Pin 6: Storage tank probe
Pin 7: Global flow Probe Ground
Pin 8: Global flow probe
Pin 9: External probe
Pin 10: External Probe Ground / Flow Probe Ground Heat. Circ. 1
Terminal VII
Terminal V
Terminal I
remote eBUS
(External cascade manager)
MODULATING PUMP CONTROL
EMERGENCY SET POINT
Connect the resistances according to the table (*)