E210501X rev.1_ENG
16/11/2021
23
ATTENTION!
Before carrying out the manual procedure, disconnect the power supply from the main switch.
ATTENTION!
The manual unlocking of the porthole closure should NEVER be used during normal operation of the machine!
In the case of washing machines with impulse closure. Open only the panel identified in the figure. To unhook
the porthole, pull the rope with a visible ring on the left side.
In the case of washing machines with motorized closure, proceed as follows:
Remove the cap (1) and insert the release lever (2) into the door block (resting on the upper edge) as in the
figure. Position the lever correctly!
Turn the lever upwards, until you hear the "click" of release.
ATTENTION!
When the motorized closure is released manually, when the electrical energy is restored, perform the closure
realignment procedure.
1
2