![Imesa TANDEM O11 Series Instructions For Installation, Use And Maintenance Manual Download Page 11](http://html1.mh-extra.com/html/imesa/tandem-o11-series/tandem-o11-series_instructions-for-installation-use-and-maintenance-manual_2046345011.webp)
E210501X rev.1_ENG
16/11/2021
11
with coin, token, or other automatic payment systems. For some machines, the heating system of the washing
machine is hot water served.
7. INDICATIONS ON NOISE EMISSION
The airborne noise produced by the machine produces an A-weighted continuous sound pressure level,
described on the data sheet attached to the machinery documentation.
8. ELECTRICAL CONNECTION
ATTENTION!
The electrical connection must be carried out by professionally qualified personnel and must meet the
requirements of current local and national rules and / or regulations. Check that the supply voltage corresponds
to that indicated in the license plate data (voltage tolerance ±10%, frequency tolerance ±1Hz).
For the connection use a cable of type H05 VV
–
F or higher sized as reported in the license plate data and in
the technical sheet. Interpose upstream of the appliance an interlocked omni polar disconnection device (e.g., a
differential magnetothermal switch) with an opening between the contacts that allows complete disconnection
under the conditions of the surge category III and complies with the relevant regulations in force. The breaking
power of the circuit breaker shall be at least 10 kA.
Make sure the main circuit breaker of the machine is in the "0/OFF
“position
.
Open the inlet door for the power supply.
Pass the appropriately sized power cable (see tables below) through the cable press supplied with the machine.
Before letting the power cord in, make sure that it performs a dead neck lower than the input, so that any
condensation drops cannot come into contact with the electrical connections.
The connection of the power supply cables must be carried out on the on-board disconnector of the machine.
Depending on the type of power supply provided by the serial number plate of the machine, connect the wires
to the terminals marked as follows:
: terminal for the equipotential connection with the grounding system of the user.
L1, L2, L3: phase terminals
N: neutral terminal
When installing or replacing the power cord, the ground conductor must be at least 5 cm longer than the others.
ATTENTION!
Check the direction of rotation of the fan: it must rotate in such a direction as to expel the air from the exhaust:
the fan motor must turn in the direction of the arrow shown on its shell. Therefore, verify that the power supply
phases are connected in the correct sequence.
ATTENTION!
The appliance must be connected to an effective ground system: the manufacturer declines all responsibility in
the event that this connection is not carried out according to the provisions of the regulations in force on the
subject.
Before any maintenance operation, disconnect the power supply: for maintenance, refer to the wiring diagram
of the machine, inserted inside the machine or available on the manufacturer's website.
The minimum sections for power cables and ground cables, expressed in
2
mm, are described in the attached
data sheet.