IMER INTERNATIONAL S.p.A
9
TRANSLATED INSTRUCTIONS
Dear Customer,
Congratulations on your choice of purchase: IMER mixers are
universal machines for MIX series: the MIX series mixers are
ideal for mixing dry or wet fine particle material (gypsum,
cement, ceramic tile adhesives, plaster, self levelling,
waterproofing or repair mortars, epoxy resin or proprietary
mixed products).
WORKING IN SAFETY
To work in complete safety, read the following instructions
carefully.
- This OPERATION AND MAINTENANCE manual must be
kept on site by the person in charge, e.g. the SITE FOREMAN,
and must always be available for consultation.
- The manual is to be considered integral part of the machine
and must be kept for future reference (EN 12100) until the
machine is disposed of. If the manual is damaged or lost, a
replacement may be requested from the saw manufacturer.
- The manual contains important information regarding site
preparation, machine use, maintenance procedures, and
requests for spare parts. Nevertheless, the installer and the
operator must both have adequate experience and knowledge
of the machine prior to use.
- To guarantee complete safety of the operator, safe operation
and long life of equipment, follow the instructions in this
manual carefully, and observe all safety standards currently in
force for the prevention of accidents at work (use of safety
footwear and gloves in accordance with S.I. N°3073 of
30/11/92).
Pay special attention to warnings bearing the following
symbol:
- MAKE SURE THAT SIGNS ARE LEGIBLE.
- It is strictly forbidden to carry out any form of
modification to the steel structure or working parts of the
machine.
- IMER INTERNATIONAL declines all responsibility for non-
compliance with laws and standards governing the use of this
equipment, in particular; improper use, defective power supply,
lack of maintenance, unauthorised modifications, and partial or
total failure to observe the instructions contained in this
manual.
1. CONDITIONS OF USE
Use of machinery in areas subject to the risk of fire or in areas
storing flammable substances or subject to flammable
emissions is strictly prohibited.
2. DESIGN STANDARDS
The Mix-ALL mixer has been designed and constructed in
accordance with the following standards: EN 12100-1/2; EN
60204-1; EN 12151.
3. NOISE EMISSION LEVEL
The noise emission level of the mixer is reported in table
(dB(A) at 1 m)and the measured sound power level L
WA
(EN
ISO 3744).
CONCRETE
MIXER
Type of
motor
dB(A)
LWA
Mix-ALL
ELECTRIC
230V 50HZ
59
73
4. OPERATION SAFETY
- The Imer Mix-ALL mixer may only be used when fitted with all
required safety devices which must be in perfect working
condition.
- Keep well clear of the mixing tank during operation.
- Never connect Mix-ALL to defective power lines.
- Make electrical connections on the construction site where
they will not be subject to damage.
- Lay power cables where they are not subject to risk of
damage or penetration of water into connectors. Only use
connectors electrically protected against water sprays.
- Never connect the mixer to makeshift mains connections. If
necessary, consult qualified personnel.
- Repairs to electrical installations must only be carried out by
qualified technicians. Do not operate the mixer during
maintenance or repairs.
- Observe all accident prevention and safety standards in the
work area.
5. ELECTRICAL SAFETY
The IMER Mix-ALL is designed in compliance with EN 60204-1
standards and features water spray protection (IP54) and
overload protection.
The mixer is also fitted with a safety system comprising a limit
switch which shuts off machine operation whenever the
reduction unit support is lifted.
To restart the mixer, you need to lower the reduction unit
support and push the green button on the electrical system.
6. ASSEMBLY
- Position the frame and handle as shown in fig.3.
- Insert the link pin and the cotter pin and tighten.
- Insert the tank in the circular housing, ensuring that the four
handles fit onto the steel brackets. to prevent tank rotation
during operation.
- Fit the safety grid, blade cover and screw the blade fully
down (fig.4).
7. TRANSPORT
- Warning: Always unplug the mixer from the power supply
before handling.
- Mix-ALL is easily transported; use the handle indicated in
fig.5 for manual transport of the mixer.
- Never use the power cable to pull the machine.
- Never pull the power cable to unplug the machine.
8. INSTALLATION
- Remove the machine from the packaging.
- Install the mixer on level and solid ground
- Do not tilt the mixer during operation.
- When transporting the machine ensure that there are no
obstacles which may impair stability.
9. ELECTRICAL CONNECTION
- The connection to electric power must be done in
accordance with CEI EN 60439-1
- Ensure that mains voltage and cable sizes correspond to
specifications.