DA-DHR/DH/DSR/DS/HR/H6802
+
Installation and Operation Manual
25
Chapter 3: Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Table 3-3.
DA-DHR6802
+
, DA-DSR6802
+
, DA-HR6802
+
Remotely Controlled Parameters
Name
Range
Description
Backup Mode
• Disable
• Enable
Loss of signal (input 1) switching enable,
automatically switch both output MUXs to select
input 2 when input 1 has lost its input signal
Output Configuration
• 1×4
• 1×8 ch. 1
• 1×8 ch. 2
Allows you to select if the card is in dual 1×4 or 1×8,
input 1 routed to all outputs; or 1×8 with input 2
routed to all outputs
Locked Data Rate [RO]
• Unknown
• 270
• HD
• HD 3.0*
• Bypass
Displays the locked input rate; if the input cannot be
locked, “Bypass” is displayed
Signal Present [RO]
• No
• Yes
Indicates if the input is present or not
Reclocking Mode
• Auto
• 270
• HD
• HD 3.0*
• Bypass
Allows you to select the reclock rate for the input
Loss of Input Alarm
• Disable
• Enable
Enables or disables the Loss of Input alarm
Loss of Lock Alarm
• Disable
• Enable
Enables or disables the Loss of Lock alarm
Slew rate*
• HD
• SD
• Auto
Allows you to specify slew rate as either HD (1.485
Gb/s or 3.0 Gb/s) or SD
* DA-DHR6802
+
only