24
DA-DHR/DH/DSR/DS/HR/H6802
+
Installation and Operation Manual
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
Chapter 3: Operation
Setting Remotely Controlled Parameters
describe parameters that are
accessible remotely. See your CCS control software application manual
or online help for more information on setting and monitoring these
parameters remotely.
Legend
Bold
option=Indicates that this is the default setting for the parameter.
[RO]=Indicates that parameters are read-only/feedback, and cannot be
used to select controls.
All parameters clip unless otherwise noted.
Table 3-2.
DA-DH6802
+
, DA-DS6802
+
, DA-H6802
+
Remotely Controlled Parameters
Name
Range
Description
Backup mode
• Disable
• Enable
Loss of signal (input 1) switching enable,
automatically switch both output MUXs to select
input 2 when input 1 has lost its input signal
Output configuration
• 1×4
• 1×8 ch. 1
• 1×8 ch. 2
Allows you to select if the card is in dual 1×4 or 1×8,
with input 1 routed to all outputs; or 1×8 with input 2
routed to all outputs
Signal present [RO]
• No
• Yes
Indicates if the input is present or not
Slew rate*
• HD
• SD
• Auto
Allows you to specify slew rate as either HD (1.485
Gb/s or 3.0 Gb/s) or SD
Loss of input alarm
• Disable
• Enable
Enables or disables the Loss of Input alarm
Loss of lock alarm
• Disable
• Enable
Enables or disables the Loss of Lock alarm
* DA-DH6802
+
only