DA-DHR/DH/DSR/DS/HR/H6802
+
Installation and Operation Manual
21
Chapter 3: Operation
Preliminary—Contents are proprietary and confidential. Do not photocopy or distribute.
J1/J2 Jumpers
You can use the J1 (for channel 1 control) or J2
1
(for channel 2 control)
jumper to select local control reclock setting.
illustrates the location of these jumpers. See
for a close-up view of the J1 jumper set.
For local control, the J1/J2 jumpers are used to determine reclocking
mode. See
“Setting Locally Controlled Parameters” on page 23
for
more information.
J3 Jumpers
illustrates the location of this jumper. See
for a close-up view of the J3 jumper set.
You can use the J3 jumper set to select the following items:
•
Remote control
: When the jumper is set to the “remote” position,
the reclocker setting is handled by
+
Pilot Lite only. You may select
the three setting modes (automatic, manual, and bypass) remotely
via
+
Pilot Lite.
•
Backup_EN
: When the BACKUP_EN switch is installed, the
module automatically selects input 2 to be an input source when
input 1 has lost its input signal. When the input signal returns, the
outputs will return to input 1 as the distribution amplifier is
configured (as 1×8 mode for DA-DHR6802
+
and DA-H6802
+
).
•
Channel configuration
: This switch allows you to configure the
module to operate as a 1×8 or as a dual 1×4 for DA-DHR6802
+
and DA-H6802
+
.
J4/J5 Jumpers
illustrates the location of this jumper. See
for a close-up view of the J4/J5 jumper set. See
for automatic and manual slew rate settings. You
can use the J4/J5 jumper set to set the output slew rate control. You can
choose from
•
Automatic slew rate
: for the reclockable input signal in
DA-DHR6802
+
and DA-HR6802
+
1
Jumper J2 is not operational in DA-HR6802
+
and DA-H6802
+
modules.