Imagine DA-DH6802+ Installation & Operation Manual Download Page 1

Delivering the Moment  

Installation and Operation Manual

DA-/ DA-:/ 
DA-/ DA-/ 
DA-/ DA-H6802+

Dual 1×4 3-Gb/s/HD / SD
Distribution Amplifiers with Reclocking/ Dual 1×4 
SD-SDI Distribution Amplifiers with Reclocking/ 
Dual 1×4 SD-SDI Distribution
Amplifiers/ Single 1×8 3-Gb/s/HD / SD Distribu-
tion Amplifiers with Reclocking/ Single 1×8 3-Gb/
s/HD / SD Distribution Amplifiers

Edition D

175-000386-00

Summary of Contents for DA-DH6802+

Page 1: ...2 DA H6802 Dual 1 4 3 Gb s HD SD Distribution Amplifiers with Reclocking Dual 1 4 SD SDI Distribution Amplifiers with Reclocking Dual 1 4 SD SDI Distribution Amplifiers Single 1 8 3 Gb s HD SD Distrib...

Page 2: ...foCaster Player Nexio InfoCaster Traffic Nexio InstantOnline Nexio mCAPTURE Nexio News Force Nexio NXIQ Nexio Playlist Nexio Remote Nexio RTX Net Nexio TitleMotion Nexio TitleOne Nexio Velocity ESX Ne...

Page 3: ...g DA DH6802 Dual 1 4 3 Gb s HD SD Distribution Amplifiers DA DSR6802 Dual 1 4 SD SDI Distribution Amplifiers with Reclocking DA DS6802 Dual 1 4 SD SDI Distribution Amplifiers DA HR6802 Single 1 8 3 Gb...

Page 4: ......

Page 5: ...acking a Product x Product Servicing x Returning a Product x Safety Standards and Compliances xi Safety Terms and Symbols xi Restriction on Hazardous Substances RoHS Directive xii Waste from Electrica...

Page 6: ...odules 18 Chapter 3 Operation Overview 19 Operating Notes 20 Understanding Jumper Controls 20 Introducing Jumper Control Types 20 J1 J2 Jumpers 21 J3 Jumpers 21 J4 J5 Jumpers 21 Understanding Paramete...

Page 7: ...DH DSR DS HR H6802 Installation and Operation Manual v Contents Chapter 4 Specifications Overview 31 Inputs 32 Outputs 33 Performance 34 Power Consumption 34 Temperature 34 Start Up Time 34 Index Keyw...

Page 8: ...vi DA DHR DH DSR DS HR H6802 Installation and Operation Manual Contents...

Page 9: ...reclocking DA DH6802 dual 1 4 3 Gb s HD SD distribution amplifiers DA DSR6802 dual 1 4 SD SDI distribution amplifiers with reclocking DA DS6802 dual 1 4 SD SDI distribution amplifiers DA HR6802 singl...

Page 10: ...l Revision History Edition Date Revision History A May 2007 Initial release B August 2007 Added information about single channel distribution amplifiers C October 2007 Removed information about single...

Page 11: ...ist boxes combo boxes menus submenus windows lists and selection names Italics Indicates email addresses the names of books or publications and the first instances of new terms and specialized words t...

Page 12: ...ons or repairs require you to return the modules to the Customer Service center Returning a Product In the unlikely event that your product fails to operate properly please contact Customer Service to...

Page 13: ...nual uses the following safety terms and symbols to identify certain conditions or practices See the 6800 Safety Instructions and Standards Manual for more information Table P 3 Safety Terms and Symbo...

Page 14: ...taminate the environment during end of life recycling The Directive which took effect on July 1 2006 refers to the following hazardous substances Lead Pb Mercury Hg Cadmium Cd Hexavalent Chromium Cr V...

Page 15: ...e products As of August 13 2005 producers or users are required to recycle electrical and electronic equipment at end of its useful life and must not dispose of the equipment in landfills or by using...

Page 16: ...xiv DA DHR DH DSR DS HR H6802 Installation and Operation Manual Preface...

Page 17: ...inary Contents are proprietary and confidential Do not photocopy or distribute Chapter 1 Introduction Overview The following topics are described in this chapter Main Features on page 2 Module Descrip...

Page 18: ...DA DS6802 dual channel SD distribution amplifiers see page 3 for a list of its main features DA HR6802 single channel 3 Gb s HD SD distribution amplifiers with reclocking see page 4 for a list of its...

Page 19: ...nly Directly fan out the input signal 5 Mb s to 3 Gb s without reclocking Card edge control by jumpers with LED display Remote control via RS 232 or Ethernet DA DSR6802 Configurable as a single channe...

Page 20: ...r 270 Mb s and remotely only Reclocking Mode selectable as automatic or manual Re lockable for 270 Mb s 1 5 Gb s and 3 0 Gb s SMPTE signal Re lockable for DVB ASI signal Reclock status and rate report...

Page 21: ...ED locations Figure 1 1 Typical Front Module Back Modules DA DHR DH DSR DS HR H6802 modules can be installed with double width back connectors in FR6802 X F and FR6802 QXF frames These modules cannot...

Page 22: ...ion and Operation Manual Preliminary Contents are proprietary and confidential Do not photocopy or distribute Chapter 1 Introduction Figure 1 2 Back Module for FR6802 XF or FR6802 QXF Frame SDI IN SDI...

Page 23: ...3 Signal Flow Diagram CCS remote monitoring and control Midplane I O Equalizer Reclocker Equalizer Reclocker 3 Gb s HD SD SDI in 1 3 Gb s HD SD SDI out 1 1 3 Gb s HD SD SDI out 1 2 3 Gb s HD SD SDI ou...

Page 24: ...8 DA DHR DH DSR DS HR H6802 Installation and Operation Manual Preliminary Contents are proprietary and confidential Do not photocopy or distribute Chapter 1 Introduction...

Page 25: ...ving Modules on page 18 Required Frames and Back Module Connector Types on page 18 Setting Jumpers on page 14 Unpacking the Module on page 11 See the FR6802 Frame Installation and Operation Manual for...

Page 26: ...er ratings for 6800 frames Note the given maximums before installing any 6800 modules in your frame DA DHR DH DSR DS HR H6802 modules can be installed in FR6802 frames They cannot be installed in 6800...

Page 27: ...equipment for any visible damage that may have occurred during transit Confirm receipt of all items on the packing list See Checking the Packing List on page 12 for more information Remove the anti s...

Page 28: ...H DSR DS HR H6802 Installation and Operation Manual DA DH6802 D One DA DH6802 front module One standard double slot back connector One DA DHR DH DSR DS HR H6802 Installation and Operation Manual DA DH...

Page 29: ...DSR DS HR H6802 Installation and Operation Manual DA HR6802 D One DA HR6802 front module One standard double slot back connector One DA DHR DH DSR DS HR H6802 Installation and Operation Manual DA HR6...

Page 30: ...power Setting J1 J2 Jumpers The J1 and J21 jumpers are used to select local control reclock setting Set the J1 jumper for input 1 rate control Set the J2 jumper for input 2 rate control Follow this p...

Page 31: ...pers The J3 jumper is used to set channel configuration control mode and enabling input backup Follow this procedure to set the jumper 1 Locate jumper set J3 on the module Figure 2 2 shows the standar...

Page 32: ...photocopy or distribute Chapter 2 Installation Setting J4 J5 Jumpers The J4 and J5 jumpers are used to set the output slew rate control Follow this procedure to set the jumpers 1 Locate the J3 and J4...

Page 33: ...ns that correspond to the slew rate you want See Table 2 4 Table 2 4 J4 J5 Jumper Set Settings Slew Rate Settings Modules Using This Setting Automatic Reclockable input signal in DA DHR6802 DA HR6802...

Page 34: ...Installing and Removing Modules These modules require no specialized installation or removal procedures However if installing both front and rear modules ensure that the back module is installed firs...

Page 35: ...operate this product remotely Pilot Lite User Manual for serial control interface CCS Navigator Pilot or RCP CCS 1U Remote Control Panel Installation and Operation Manual for Ethernet control interfa...

Page 36: ...When you change a control parameter on a DA DHR DH DSR DS HR H6802 module the effect is immediate However the module requires up to 20 seconds to save the latest change After 20 seconds the new settin...

Page 37: ...ition the reclocker setting is handled by Pilot Lite only You may select the three setting modes automatic manual and bypass remotely via Pilot Lite Backup_EN When the BACKUP_EN switch is installed th...

Page 38: ...ers that are considered read only and cannot be changed Indicated by the abbreviation RO these parameters provide status and feedback information only Harris recommends that you use the available 6800...

Page 39: ...ill be AUTO 270 Forces channel to lock to a 270 Mb s signal Set the jumper on the pin that allows the reclocker to handle 270 Mb s data only If 270 reclock mode is selected the 270 Mb s LED will turn...

Page 40: ...parameters clip unless otherwise noted Table 3 2 DA DH6802 DA DS6802 DA H6802 Remotely Controlled Parameters Name Range Description Backup mode Disable Enable Loss of signal input 1 switching enable...

Page 41: ...you to select if the card is in dual 1 4 or 1 8 input 1 routed to all outputs or 1 8 with input 2 routed to all outputs Locked Data Rate RO Unknown 270 HD HD 3 0 Bypass Displays the locked input rate...

Page 42: ...lot Lite menu bar select File Refresh For information about controlling a device using Pilot Lite see your Pilot Lite User Manual Discovering Your Module Using CCS Software To discover your DA DHR DH...

Page 43: ...ndow opens displaying the module s controls Recalling Default Parameter Settings You cannot recall default parameter settings for DA DHR DH DSR DS HR H6802 modules Reading the Software and Hardware Ve...

Page 44: ...ule Status Indicator LED A module status LED reports the state of the module See Figure 3 1 on page 20 for the location of this LED and Table 3 4 for a definition of the LED colors Table 3 4 Module St...

Page 45: ...umber of LEDs assigned to indicate varying states functions These functions are listed in Table 3 5 Table 3 5 Module Specific Status LEDs Name Color Function 270 Green Input signal is reclocked at 270...

Page 46: ...6802 module the Status LED will turn off Alarms are usually logged and monitored within the available 6800 software control applications for example Pilot Lite or Pilot See the appropriate software co...

Page 47: ...not photocopy or distribute Chapter 4 Specifications Overview The following specification tables appear in this chapter Inputs on page 32 Outputs on page 33 Power Consumption on page 34 Performance on...

Page 48: ...ual channel mode Single channel mode 1 each channel 1 Signal type 3G HD SD ASI Connector BNC per IEC169 8 Impedance 75 Return loss 15 dB to 1 5 GHz 10 dB 1 5 GHz to 3 0 GHz Maximum signal level 0 88 V...

Page 49: ...ations Item Specification Number of outputs Dual channel mode Single channel mode 4 each channel 8 Signal type 3G HD SD ASI Connector BNC per IEC169 8 Impedance 75 Return loss 15 dB 5 MHz to 1 5 GHz 1...

Page 50: ...on Module power consumption is 6 W Temperature Start Up Time Module start up time is approximately 3 seconds Table 4 3 Performance Specifications Item Specification Jitter 0 2 UI for reclocking DA 0 3...

Page 51: ...2 LEDs 28 29 packing list 12 reclock modes 14 23 remote parameters 24 setting jumpers 14 17 20 22 signal flow 7 specifications input specifications 32 output specifications 33 performance specificatio...

Page 52: ...power consumption 34 start up time 34 temperature specifications 34 DA H6802 alarms 30 applications 4 description back module 5 6 features 4 front module 5 product 2 LEDs 28 29 packing list 13 reclock...

Page 53: ...al flow diagrams 7 J K Jumpers controls Backup_EN switch 21 channel configuration switch 21 control types 20 local control 23 remote control 21 understanding jumper controls 20 23 J1 14 21 23 J2 14 21...

Page 54: ...ontrolled 24 25 setting parameters 23 25 Performance specifications 34 Power consumption specifications 34 Power ratings 10 Power up time 34 Preparing for installation 11 Product description 2 R Read...

Page 55: ......

Page 56: ...0 Tel 1 513 459 3400 www broadcast harris com 2008 Harris Corporation Harris is a registered trademark of Harris Corporation Trademarks and tradenames are the property of their respective companies Cu...

Reviews: