Chapter 3
Operation
76
The following settings can be made for each alarm within Pilot or Navigator software.
describes the specific alarms for the SFS6803
+
and OP
+
SFS
+
. You can only
identify specific alarms using a software control application.
Table 3-15
Alarm Options
Alarm Option
Effect
Enable/Disable
This option toggles between Enabled and Disabled. If the alarm
is
Enabled
, an alarm condition generates an alarm; but if it is
Disabled
, the alarm condition is ignored. By default, all alarms
are disabled.
Alarm priority
This setting determines whether a triggered alarm is reported as
major or minor. The range is 1–10. A priority of 6 or higher is a
major alarm, and a priority of 5 or lower is a minor alarm
Trigger (s)
This option determines how long an alarm condition must exist
(in seconds) before the alarm is triggered. If the alarm level is
reached for less time than the
Trigger
duration, then the alarm
will not trigger. Choose any duration from 0 to 7200 seconds (or
2 hours). If this option is set to 0 and the alarm condition exists
for any period of time, the alarm is triggered.
Clear (s)
Determines the amount of time the alarm condition must be in
abatement in order for the alarm to be turned off. Choose any
duration from 0 to 7200 seconds (or 2 hours). If this option is set
to 0 and the alarm condition ceases for any period of time, the
alarm is cleared.
Ack
When an alarm is active, click this option to allow other users on
the network to see that you have acknowledged the alarm.
Table 3-16
Alarm Definitions
Alarm Name
Alarm Option Default Settings
Priority
Trigger
Clear
Video Standard Mismatch
8
1 sec
2 sec
Unsupported Video Standard
8
1 sec
2 sec
Loss of Electrical SDI Input
9
1 sec
2 sec
Loss of Optical SDI Input
6
1 sec
2 sec
DMX Ch (1-16) Silent
1
30.0 s
0.0 s
DMX Ch (1–16) Peak
6
0.0 s
0.0 s
Input AES (1A-8B) Silent
1
30.0 s
0.0 s
Input AES (1A-8B) Peak
6
0.0 s
0.0 s
DMX Group(1–4) Checksum Error
1
2 sec
2 sec
DMX Group (1–4) DBN Error
1
2 sec
2 sec
DMX Group (1- 4) ECC Error
1
2 sec
2 sec
DMX Group (1–4) Parity Error
1
2 sec
2 sec
Embedded Audio Group (1–4) Missing
1
2 sec
2 sec
Loss of DARS Input (with AES option)
1
2 sec
2 sec
Summary of Contents for Selenio 6800 SFS6803+OP+SFS+
Page 4: ......
Page 8: ...Contents vi Hardware Communication Problems 99 Index 101...
Page 92: ...Chapter 3 Operation 78...