Locate the four threaded screw holes on each side of the chassis and align them with the first four
holes of the inner slides.
Figure 14:
Slide Mounting
3.
Secure the slide to the chassis with the supplied screws.
4.
Repeat the above steps to install the other inner slide on the opposite side of the chassis.
Rack Mount Safety Instructions
1.
Elevated Operating Ambient:
If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with the
maximum ambient temperature (Tma) specified by the manufacturer.
2.
Reduced Air Flow:
Installation of the equipment in a rack should be such that the amount of air flow
required for safe operation of the equipment is not compromised.
3.
Mechanical Loading:
Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
4.
Circuit Overloading:
Consideration should be given to the connection of the equipment to the
supply circuit and the effect that overloading of the circuits might have on overcurrent protection
and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
5.
Reliable Earthing:
Reliable earthing of rack-mounted equipment should be maintained. Particular
attention should be given to supply connections other than direct connections to the branch circuit
(e.g. use of power strips).
Rack Mount the Chassis
After you have installed the inner slides on the chassis, you are ready to install the outer slides to the
rack.
1.
Insert the intermediate slide fully into the outer slide from the rear until it locks in place.