Doc no: 430-041-01
64 of 64
No
Check
Document No
Page
Software configuration
30. Set Range (1.5 to 2 X water depth)
430-040-00
7
31. Set Gain (start at 10 dB and adjust)
430-040-00
7
32. Set Display Gain (50%)
430-040-00
33. Set-up IP addresses
430-040-00
11
34. Set-up units
430-040-00
11
35. Set-up max file size if required
430-040-00
11
36. Set-up heading input port (Gyro or DGNSS)
430-040-00
12
37. Set-up MRU Input port (Integrated or external MRU)
430-040-00
12
38. Set-up sound velocity source
430-040-00
12
39. Enable Overlap Sonar I/O (for faster ping rate)
430-040-00
12
40. Set-up sector size
430-040-00
13
41. Set-up number of beams
430-040-00
13
42. Set-up averaging
430-040-00
13
43. Enable gain equalization
430-040-00
13
44. Enable Automatic Gain Control
430-040-00
17
45. Select preferred profile point display (Usually High mix)
430-040-00
18
46. Set Profile Point Detection Min and Max (text box or handles)
430-040-00
18
47. Select Profile Point Filter type.
430-040-00
19
48. Select Display settings
430-040-00
19
49. Apply Roll Correction
430-040-00
20
50. Apply tilt angle
430-040-00
21
51. Ensure Data Output is set to D1P for most applications
430-040-00
22
No
Check
Document No
Page
Operation
52. Conduct regular SV cast
430-0
41
-00
18
53. Log .IGX file
430-0
40
-00
9
Summary of Contents for DT101Xi
Page 35: ...Doc no 430 041 01 35 of 64 APPENDIX A DT101Xi DT102Xi SPEC SHEETS DT101Xi...
Page 36: ...Doc no 430 041 01 36 of 64...
Page 37: ...Doc no 430 041 01 37 of 64...
Page 38: ...Doc no 430 041 01 38 of 64...
Page 39: ...Doc no 430 041 01 39 of 64 DT102Xi...
Page 40: ...Doc no 430 041 01 40 of 64...
Page 41: ...Doc no 430 041 01 41 of 64...
Page 42: ...Doc no 430 041 01 42 of 64...
Page 52: ...Doc no 430 041 01 52 of 64 Figure 6 7 Jumpers for Heading and PPS Selection...