![background image](http://html1.mh-extra.com/html/illunis/rmv-11002/rmv-11002_operation-manual_2044107039.webp)
RMV Operations Manual Revision Copyright illunis LLC, 2014
Page 39
Mode Register #4
Bit Name
Description
15
C Data Checksum
14
115200 Baud Enabled
13
57600 Baud Enabled
12
38400 Baud Enabled
11
19200 Baud Enabled
10
9600 Baud Enabled
9
Trigger Overlap Exposure
8
Trigger Partial Scan Enabled
7
Not Used
OSD screen type bit 2
6
Not Used
OSD screen type bit 1
5
Not Used
OSD screen type bit 0
4
Trigger PDC Enabled
3
Trigger LUT Enabled
2
Trigger DGO Enabled
1
Trigger Decimate
0
Trigger Bin
Mode Register #5
Bit Name
Description
15
AE Time base algoritm
Always 1 for Rev E
14
Trigger Bayer Bin
13
FFC Table loaded
12
11
Show AF data full screen
10
Show AF Data
9
Show SNR Right Detector Window
8
Show SNR Left Detector Window
7
Show AF Detector Window
Auto Focus detector window
6
Show AE Detector Window
Auto Exposure detector window
5
Show Tap B Crack Detector Window
Tap B is the Left Tap of the CCD
4
Show Tap A Crack Detector Window
Tap A is the Right Tap of the CCD
3
TBD
2
Power Down
1
AE Close IRIS Request
Indicates to the user control software that the image is to bright
0
AE Open IRIS Request
Indicates to the user control software that the image is to dim