Mode Register #2
Bit
Name
Description
15
4 Tap CCD Readout
14
2 Tap CCD Readout
13
1 Tap CCD Readout
12
Over Scan Enabled
Sensor Over Scan
11
PDC Column Mode
PDC: 0 = Pixel correction, 1 = column correction mode
10
Channel Swap Enabled
Swaps camera link channels in dual channel mode
9
Not Used
8
Bottom 8 Readout
Outputs the bottom 8 bits of the 12 bit ADC data as the 8 msb’s
7
8 Bit Readout
Camera link readout mode
6
10 Bit Readout
Camera link readout mode
5
12 Bit Readout
Camera link readout mode
4
Tap Matcher Status
1 = on, 0 = off
3
Frame/Line Clamp Mode
0 = Line Clamp, 1 = Frame Clamp (Not recommended)
2
ASYNC RESET Enabled
Allows triggered frames in Free Run Mode
1
LUT loaded
OEM
0
OSD 2X Enabled
Mode Register #3
Bit
Name
Description
15
SRC Over scan
Adds 16 lines of over scan to the sensor readout
14
SRC Wave
13
SRC Average
Averages data in smear reduction circuit
12
OSD Filled Plot
11
SRC Enable
Smear Reduction Correction
10
OSD Column Enabled
9
OSD Line Enabled
8
Free Run Partial Scan Enabled
OEM Only
7
Trigger Source External
6
Flush Gate
5
OSD Color Mode
Enlarges the tap match window to two pixels wide to handle Bayer patterns
4
Free Run PDC Enabled
3
Free Run LUT Enabled
OEM Only
2
Free Run DGO Enabled
DGO = Digital Gain & Offset
1
Free Run Decimation Mode
0
Free Run Bin Mode