If the RMV is set to four tap readout, the camera output the four taps on two channels
of the CameraLink bus. In the diagram below show a two tap readout. Four image paths from
the CCD at 40Mhz is processed and sent to the frame grabber on two CameraLink channels
( Taps ).
The rate of data sent to the frame grabber is doubled to compensate for twice the data enter-
ing the camera electronics.
The frame grabber get the image as if it were a two tap camera. One tap is left to right, top to
middle. The other tap is left to right, bottom to middle.
CCD
Camera
Electronics
Frame
Grabber
4 Paths at
40Mhz
2 Paths at
80Mhz
4 tap data path