3.3: Software ICD
Command Table
Target
Index
Description
Read
Write
Modes
Camera Control
04
00
Sensor Taps
Write
0x0000 = One Tap
0x0001 = Two Tap
0x0003 = Four Tap
04
03
Readout Mode Select
Write
0x0000 = Free Run
0x0001 = Trigger Program Exposure
0x0002 = Trigger Manual Exposure
0x0003 = Trigger Double Exposure
0x0004 = Reserved (Do Not Used)
0x0005 = Async Reset Enabled
0x0006 = Async Reset Disabled
0x0007 = Enable Runs Valids
0x0008 = Disable Runs Valids
0x0009 = Trigger Source CL
0x000a = Trigger source External (OEM
0x000b = Trigger Overlap Exposure Enable
0x000c = Trigger Overlap Exposure Disable
0x000d = Double Trig, Double Expos (OEM)
04
04
Mode Register
write lines to 0428 and
0429 prior to binning
M = 0 Common – both
trigger and free run
M = 8 Free Run Only
M = 4 Trigger Only
Write
0xM000 = Bin enable
0xM001 = TBD
0xM002 = Disable bin
0xM003 = Enable partial Scan
0xM004 = Disable Partial Scan
0xM005 = Enable Digital Gain and offset
0xM006 = Disable Digital Gain and offset
0xM007 = Enable LUT
0xM008 = Disable LUT
0xM009 = Enable PDC enables once loaded
(call 041c000b first which leaves PDC on in
common mode)
0xM00a = Disable PDC
0x000F = Enable Bayer Bin
0x0010 = Disable Bayer Bin
0x0011 = Enable FFC (OEM Only)