95
6.4
OVP
– Output Voltage Protection
Displayed if the output voltage has exceeded 5 V of the setting voltage in the
0-150V range, or has exceeded 10 V of the setting voltage in the 0-300V range.
The LED indicator for the Test/Reset key will be blinking.
If an OVP error occurs on the next power up cycle on the displays will show
Volt Err.
6.5
A-SH
– Amplifier Shutdown Protection
Displayed if the amplifier is in an abnormal condition. The LED indicator for the
Test/Reset key will be blinking.
6.6
RCP
– Reverse Current Protection
Displayed if the power source detects negative current feeding back into the
source. RC
P will trip when negative power exceeds 75W of the instrument’s full
power. The LED indicator the Test/Reset key will be blinking.
6.7
LVP
– Low Voltage Protection
Displayed if the power source detects a discrepancy between the output voltage
setting of 10V or greater for more than 1 sec. The LED indicator the Test/Reset
key will be blinking.