6-4.DI (Sensor Input) / DO (Alarm Output)
Click DI/DO item on Menu, below Setup screen is displayed.
It can be set Sensor input and Alarm Output.
Sensor
Input Name
Print in Sensor name
Enter up to 31 alphanumeric characters or up to 15 Unicode.
Alarm
Output Name
Print in Alarm name
Enter up to 31 alphanumeric characters or up to 15 Unicode.
Sensor
Input Type
Select Normal Open:
Normal is OPEN, and goes Closed when triggered by an event.
Select Normal Close:
Normal is CLOSE, and goes opened when triggered by an event.
Alarm
Output Type
Select Normal Open:
Normal is OPEN for relayed output, and closed when triggered by event.
an event.
Select Normal Close:
Normal is CLOSE for relayed output, and opened when triggered by an
event.
After finished above setting, click Apply button to save settings.
If click Back button, new setting data will be cancelled and the screen will be back to previous
screen display.
Note:
Make sure type of the sensor and use it correctly to the type.
If a Sensor Input is not used, it must be set Normal Open Type to avoid a false input.
32