93
HDK-99 1803 VER1 (E)
5
CAMERA SETTINGS and ADJUSTMENT
5.2 Settings from the Menu
Menu Item
Initial
Setting
Setting Value
Description, Remarks
MENU DATA
ALL
VF
―
FLEXIBLE MODE
Mode which creates a flexible gamma curve.
―
DEFAULT RESET
CANCEL
CANCEL, START
It restores the created custom gamma data to the original
condition.
‐
‐
―
SELECT
NORMAL
NORMAL, CUSTOM1 to
5
It selects a gamma table to create.
‐
‐
―
POINT
100%
35% to 440%
It sets a certain point of the video level before applying the
gamma function.
‐
‐
―
WIDTH
60%
20% to 100%
It sets the video level width. The signal with the stripe
pattern indicates the range of video level to be adjusted.
‐
‐
―
LEVEL
0
-100 to 100
It adjusts the level range that was set in "POINT" and
"WIDTH." It can change the level while keeping the smooth
curve with a focus on the point.
‐
‐
CAL
OFF
OFF, CAL100%,
CAL200%, CAL300%,
CAL400%, CAL600%
It selects a test waveform (CAL) to check the gamma table.
‐
‐
―
SHUTTER
OFF
OFF, PRESET,
VARIABLE
Selects the electronic shutter.
-
-
―
SHUTTER SPEED
1/100
PRESET:1/100 to 1/2000
VARIABLE:1/60 to 1/9633
Changes the shutter speed.(Only when SHUTTER is
PRESET and VARIABLE)
-
-
―
GAMMA CURVE COPY
CUSTOM 1 to 5
> CUSTOM 1 to 5
Copies the created custom gamma data to other data in the
camera.
-
-
―
SD MEMORY CARD
―
SAVE
Saves the custom gamma data to SD card.
LOAD
Reads the custom gamma data from the SD card.
Function to load the user settings (ENGINEER SET FILE)
or factory settings (FACTORY SET FILE) for the level
adjustment or menu of the camera.
Used to return the camera state back to the previous or initial
settings.
PRESET FILE LOAD
―
FILE SELECT
ENGINEER
ENGINEER, FACTORY
ENGINEER : Initializes the state back to the user setting.
FACTORY : Initializes the state back to the initial factory
setting.
-
-
LOAD START
READY
READY, START,
CANCEL
Executes initialization.
-
-
*2 : When compiling ABB/AWB reference files from the menu, No. 2 of S3 of the MPU_MULTI_B module must be turned ON.
When changing the switch, be sure to first turn the power OFF.
After compiling the reference file, be sure to return No. 2 of S3 to OFF.
When compiling the reference file from the control panel, it is not necessary to turn this switch ON.
*3
:
With the CUSTOM GAMMA MODE - LOAD menu, it reads the custom gamma data from the SD CARD.
Summary of Contents for FA-97A
Page 1: ...HIGH DEFINITION CAMERA SYSTEM HDK 99 FA 97A OPERATION MANUAL...
Page 2: ......
Page 17: ...1 OUTLINE...
Page 18: ......
Page 24: ......
Page 26: ......
Page 27: ...2 NAME and FUNCTION...
Page 28: ......
Page 47: ...3 INSTALLATION and CONNECTION...
Page 48: ......
Page 50: ...34 HDK 99 1803 VER1 E...
Page 52: ......
Page 54: ......
Page 70: ......
Page 71: ...4 OPERATION...
Page 72: ......
Page 88: ......
Page 89: ...5 CAMERA SETTINGS and ADJUSTMENT...
Page 90: ......
Page 126: ......
Page 127: ...6 TROUBLE SHOOTING and MAINTENANCE...
Page 128: ......
Page 138: ......
Page 139: ...7 SPECIFICATIONS...
Page 140: ......
Page 144: ...128 HDK 99 1803 VER1 E 7 2 External Dimensions Diagram Left View 94 3 7 1 337 5 270 5...
Page 160: ......
Page 162: ......
Page 164: ......
Page 165: ......