SuperiorFireplaces.us.com
900463-01E
31
SPECIFICATIONS
MNF24IPM
MNF24IPV
MNF30IPM
MNF30IPV
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Propane/LP
• Ignition: Electronic
• Manifold Pressure: 7.9" W.C.
• Inlet Gas Pressure (in. of water):
Max - 14" W.C., Min* - 11" W.C.
*For purpose of input adjustment
MNF24INM
MNF24INV
MNF30INM
MNF30INV
• Rating (Variable): 29,000/40,000 Btu/Hr
• Type Gas: Natural
• Ignition: Electronic
• Manifold Pressure: 3.4" W.C.
• Inlet Gas Pressure (in. of water):
Max - 10.5" W.C., Min* - 5" W.C.
*For purpose of input adjustment
To Thermopile
To AUTO Terminal on
Switch
To OFF Terminal on
Switch
WIRING DIAGRAM (REMOTE READY MODELS)
WIRING DIAGRAM (VARIABLE CONTROL MODELS)
Black Connectors
Receiver
To Thermopile
White
Red
NOTE: For proper operation of remote control, wires from thermopile to control receiver must be con-
nected exactly as shown.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors