SuperiorFireplaces.us.com
900463-01E
16
PRESSURE TESTING APPLIANCE GAS
CONNECTIONS
1. Open equipment shutoff valve
(see
Figure 15,
Page 15
).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of appliance is in the
OFF position.
4. Check all joints from gas meter to equipment
shutoff valve for natural gas or propane/LP
supply to equipment shutoff valve for propane/
LP
(see
Figure 16, Page 15
or
Figure 17, Page
16
)
. Apply noncorrosive leak detection fl uid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light appliance
(see Operation,
Page 23
)
.
Check all other internal joints for leaks.
7. Turn off appliance (see
To Turn Off Gas to Ap-
pliance
,
Page 25
for Remote Ready models or
Page 27
for Variable Remote Models.
INSTALLING SWITCH (REMOTE READY
MODELS)
The AUTO/OFF/ON switch for this log set is installed
into the small single log accompanying this log set.
This switch needs to be used only if remote or wall
switch is not being used.
Gas Meter
Figure 17 - Checking Gas Joints (Natural Gas
Only)
Control Valve
Location
Equipment Shutoff Valve
INSTALLATION
Continued
Figure 18 - Connecting Wires
Control Valve
To AUTO
Terminal on
Switch
To OFF
Terminal on
Switch
WARNING: Turn off appliance and
let cool before handling any part of
appliance. Make sure gas is turned
of to unit.
WARNING: A qualifi ed service per-
son must connect and disconnect gas
to appliance. Follow all local codes.
Connect the wires to the valve from the switch
assembly as shown in
Figure 18
.
INSTALLING OPTIONAL REMOTE
ACCESSORIES (REMOTE READY MODELS)
Installing Remote Receiver
Remote control accessories are available separately
(see Accessories,
Page 40
)
. Read instructions
shipped with remote control along with instructions
below before attempting installation.
1. If unit is already installed in fi replace, continue
with these instructions. If unit has not been
installed in fi replace, go to step 6 and continue
installation of remote accessory.
2. Carefully remove logs and set aside.
3. Locate mounting screws on sides of appliance
base assembly and remove screws. Set screws
aside for reinstallation.
4. Disconnect gas line from appliance base as
shown in
Figure 11, Page 13
.
5. Remove appliance base from fi replace.
6. If installed, disconnect AUTO/OFF/ON switch
wire from control valve at TPTH and TH loca-
tions
(see
Figure 19
)
.
7. Connect wires from hardware pack (with re-
mote receiver bracket) to control valve at the
TPTH and TH locations as shown in
Figure 19
.
Connect other ends of these wires to remote
receiver wires.
NOTE
: Make sure excess wire does not interfere
with burner or pilot.
8. If appliance was removed from fi replace before
installation of remote accessory, see
Installing
Appliance Base Assembly
on
Page 12
to reinstall
appliance into fi replace. Test gas connection for
leaks
(see Checking Gas Connections,
Page 15
).